Bayesian-Optimized ANN for Predicting the Thermodynamic and Exergy Performance of an Automobile HVAC Compressor Using R1234yf
Compressors are the most energy-consuming components of automobile heating, ventilation, and air conditioning systems. Thus, compressor performance mapping and accurate predictions are vital for enhancing the energy efficiency of these systems. In this work, an artificial neural network (ANN) model with Bayesian optimization was employed to predict the thermodynamic and exergetic performance of a 160 cm3 fixed-displacement swash-plate compressor using R1234yf as the refrigerant. For modeling, 2574 experimental samples were obtained under different operating conditions, using compressor speed, indoor air temperature, indoor airflow rate, outdoor air velocity, and the measured suction state (temperature, pressure, specific volume, enthalpy, and entropy) as inputs, and were randomly split into training, validation, and test subsets (65/15/20%), stratified by compressor speed. With the considered input parameters, the refrigerant mass flow rate, discharge pressure, pressure ratio, discharge temperature, compressor power (electrical and refrigerant sides), volumetric efficiency, isentropic efficiency, overall efficiency, compressor exergy destruction, and exergy efficiency were predicted. Initially, Bayesian optimization was used to determine the ANN architecture and training parameters, followed by hyperparameter sensitivity, training and validation loss, residual distribution, and prediction error analyses. The optimized ANN provided coefficient of determination (R2) values above 0.95 for all parameters except overall efficiency (0.82), while the mean absolute percentage error (MAPE) did not exceed 1.65% for all predictions (independent test subset). The highest accuracy was obtained for electrical compressor power, with an R2 of 0.9998 and MAPE of 0.29%. The predictions of refrigerant mass flow rate, pressure ratio, compressor exergy destruction, and exergy efficiency also showed very good agreement with the experimental results, with R2 values of 0.9988, 0.9991, 0.9994, and 0.9891, respectively. Volumetric efficiency was predicted more accurately than isentropic and overall efficiencies, with an R2 of 0.9974 and MAPE of 0.59%. Grouped five-fold cross-validation by operating condition reduced the mean R2 from 0.977 to 0.807, and overall efficiency (R2 = −0.11) did not generalize to unseen conditions. The results demonstrate the capability of the optimized ANN to predict the investigated compressor performance parameters within the experimental operating domain. However, the model was developed for a specific 160 cm3 swash plate compressor configuration under a fixed refrigerant charge and thermostatic expansion valve setting. Therefore, its applicability to other compressor configurations, refrigerant charge levels, thermostatic expansion valve settings, and operating conditions beyond the investigated experimental ranges requires further experimental validation.
Authors
- P. Jeyalakshmi
- Rajendran Prabakaran (ORCID: https://orcid.org/0000-0002-3341-0036)
- B. Gomathi (ORCID: https://orcid.org/0000-0002-3632-9858)
- Thangamuthu Mohanraj (ORCID: https://orcid.org/0000-0002-4866-1428)
- Sung Chul Kim
Institutions
- PSG INSTITUTE OF TECHNOLOGY AND APPLIED RESEARCH (IN)
- Yeungnam University (KR)
- Amrita Vishwa Vidyapeetham (IN)
Publication Details
- Journal
- Machines
- Published
- 2026-11-26
- DOI
- https://doi.org/10.3390/machines14121407
- Primary Topic
- Refrigeration and Air Conditioning Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00