Comparison of the Physical Properties of Injectable Composite Resins with Those of Conventional Flowable and Packable Composite Resins: An In Vitro Study

This study aimed to compare the surface roughness, microhardness, and compressive strength of injectable composite resins with those of conventional flowable and packable composite resins. Two injectable composite resins (ES Flow Plus Injectable [ESF] and G-ænial Universal Injectable [GI]), one flowable composite resin (Filtek Supreme Flowable Restorative [FF]), and one packable composite resin (Filtek Z250 [Z250]) were evaluated, with ten specimens per group for each test. Disk-shaped specimens were used for the surface roughness and microhardness tests, and cylindrical specimens for the compressive strength test. The polished surfaces were additionally examined by scanning electron microscopy. Data were analyzed using the Kruskal-Wallis test followed by the Mann-Whitney U test with Bonferroni correction. FF showed significantly lower surface roughness than ESF and Z250 (p = 0.004 and p = 0.013), whereas the difference from GI was not significant (p = 0.111). Z250 showed the highest microhardness, and both ESF and GI showed significantly higher microhardness than FF (p < 0.0001). No significant difference in compressive strength was detected among ESF, GI, and Z250, whereas FF showed significantly lower compressive strength than the other three materials (p < 0.0001). Within the limitations of this study, the injectable composite resins show higher microhardness and compressive strength than the flowable composite resin, although their surface roughness exceeds the reported plaque-retention threshold. As flow, handling, and cavity adaptation were not evaluated, these findings indicate potential clinical applicability limited to the properties measured here and require confirmation under aging conditions.

Authors

Institutions

Publication Details

Journal
THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
Published
2026-11-26
DOI
https://doi.org/10.5933/jkapd.2026.53.4.476
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparison of the Physical Properties of Injectable Composite Resins with Those of Conventional Flowable and Packable Composite Resins: An In Vitro Study

Miran Han, Joonhaeng Lee, Jisun Shin, Yu-Jin Kim et al.
THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
Dental materials and restorations
article

Comparison of the Physical Properties of Injectable Composite Resins with Those of Conventional Flowable and Packable Composite Resins: An In Vitro Study

Miran Han, Joonhaeng Lee, Jisun Shin, Yu-Jin Kim, 정지훈, Jongbin Kim, Jong-Soo Kim
article en

Abstract

This study aimed to compare the surface roughness, microhardness, and compressive strength of injectable composite resins with those of conventional flowable and packable composite resins. Two injectable composite resins (ES Flow Plus Injectable [ESF] and G-ænial Universal Injectable [GI]), one flowable composite resin (Filtek Supreme Flowable Restorative [FF]), and one packable composite resin (Filtek Z250 [Z250]) were evaluated, with ten specimens per group for each test. Disk-shaped specimens were used for the surface roughness and microhardness tests, and cylindrical specimens for the compressive strength test. The polished surfaces were additionally examined by scanning electron microscopy. Data were analyzed using the Kruskal-Wallis test followed by the Mann-Whitney U test with Bonferroni correction. FF showed significantly lower surface roughness than ESF and Z250 (p = 0.004 and p = 0.013), whereas the difference from GI was not significant (p = 0.111). Z250 showed the highest microhardness, and both ESF and GI showed significantly higher microhardness than FF (p < 0.0001). No significant difference in compressive strength was detected among ESF, GI, and Z250, whereas FF showed significantly lower compressive strength than the other three materials (p < 0.0001). Within the limitations of this study, the injectable composite resins show higher microhardness and compressive strength than the flowable composite resin, although their surface roughness exceeds the reported plaque-retention threshold. As flow, handling, and cavity adaptation were not evaluated, these findings indicate potential clinical applicability limited to the properties measured here and require confirmation under aging conditions.

THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRYVol. 53(4)
Dankook University (KR)
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon