Lightweight convolutional neural networks for detecting middle cerebral artery stenosis on TCD spectral images: discriminative performance, probability calibration and deployment value
Background Transcranial Doppler (TCD) is a portable bedside tool for screening middle cerebral artery (MCA) stenosis, but its accuracy depends strongly on operator experience. Most reported deep-learning studies optimize one architecture and assess discrimination only, leaving open the architecture’s point-of-care cost and whether its output probability can be trusted. Methods In this retrospective single-center study, 1,835 TCD spectral images (1,641 development; 194 held-out) were analyzed per vessel-side image. Four backbones spanning a 7.7-fold parameter range—ResNet50, EfficientNet-B0, EfficientNetV2-S, MobileNetV3-Large—shared a head under unified fine-tuning. The candidate was chosen by a rule that fixes discrimination eligibility on development-cohort out-of-fold predictions and then ranks the eligible backbones by measured CPU cost, applied before any held-out-cohort scoring: lowest CPU latency among backbones whose development-cohort AUC was statistically indistinguishable from the best. Protocols used validation-only grid search; the loss was ablated; readiness was assessed via ECE, Brier, Murphy decomposition, Grad-CAM. Results All backbones showed statistically indistinguishable held-out discrimination (AUC 0.9995–0.9999; every paired bootstrap ΔAUC 95% CI included zero), while cost differed by an order of magnitude: MobileNetV3-Large used 7.7 × fewer parameters and 19 × fewer FLOPs than ResNet50, ran 1.6–9.5 × faster, and matched it within noise. The rule selected MobileNetV3-Large as primary (EfficientNet-B0 secondary); FLOPs did not predict CPU latency. Validation-only temperature scaling reduced ECE to 0.0102–0.0161; residual Brier was almost entirely reliability. Conclusion For TCD-based MCA stenosis detection, discrimination saturated across backbones spanning an order of magnitude in cost; in this single-center dataset, deployment cost therefore provided a pragmatic criterion for architecture selection rather than AUC. This single-center, single-device retrospective study does not establish external generalization; multicenter prospective validation formally remains required before clinical use.
Authors
- Na Li (ORCID: https://orcid.org/0000-0002-4761-5921)
- Qian Zhao (ORCID: https://orcid.org/0000-0003-0304-8854)
- Li Sun
- Xiaoping Zhang
Institutions
- Central Hospital Affiliated to Shenyang Medical College (CN)
Publication Details
- Journal
- Frontiers in Neurology
- Published
- 2026-11-26
- DOI
- https://doi.org/10.3389/fneur.2026.1960825
- Primary Topic
- Cerebrovascular and Carotid Artery Diseases
- Type
- article
- Field-Weighted Citation Impact
- 0.00