Loss of mains detection methods in photovoltaic inverters – analysis and experimental verification
The paper presents Loss of Mains detection methods applied in grid-connected inverters cooperating with renewable energy sources. The passive RoCoF method and the active RPI method were implemented in a single-phase photovoltaic inverter and experimentally verified. Tests were performed according to EN 62116:2014, with reference to EN 50438:2013 and EN 50549-1:2019. RPI detected LoM at all investigated operating points, while simultaneous operation of both algorithms reduced the detection and disconnection time.
Authors
- Andrzej Niedworok (ORCID: https://orcid.org/0000-0001-5234-0531)
Publication Details
- Journal
- PRZEGLĄD ELEKTROTECHNICZNY
- Published
- 2026-11-26
- DOI
- https://doi.org/10.15199/48.2026.11.3
- Primary Topic
- Islanding Detection in Power Systems
- Type
- article
- Field-Weighted Citation Impact
- 0.00