Antenatal point-of-care ultrasound in low- and middle-income countries: a systematic review

Objective: To identify, evaluate, and synthesise reported applications of antenatal point-of-care ultrasound (POCUS) in low- and middle-income countries (LMICs). Design: Systematic review done in accordance with PRISMA 2020 and prospectively registered with PROSPERO (CRD42023410005). Methods: We searched EMBASE, CINAHL, The Cochrane Library, Global Health Library, MEDLINE, PubMed, and Web of Science Core Collection from inception to Dec 12, 2024. POCUS was defined as focused ultrasonographic imaging performed and interpreted in real time by the treating provider. We included peer-reviewed original studies reporting antenatal POCUS use in LMICs, with no restriction on study design, publication date, or language. Methodological quality was assessed with the Mixed Methods Appraisal Tool (MMAT), and reported applications were mapped by trimester usingInternational Society of Ultrasound in Obstetrics and Gynaecology (ISUOG) guidance to identify evidence gaps. Results: The search identified 6012 records, of which 30 studies were included. Studies were conducted in 17 countries, 68% in Africa. Most used quantitative designs; four were qualitative. Five studies evaluated machine learning or artificial intelligence for gestational age estimation, fetal presentation, or placental location. The most commonly reported POCUS applications were gestational age determination (23/30), placental location (20/30), fetal presentation (19/30), cardiac activity (17/30), biometry (15/30), fetal number (14/30), and amniotic fluid volume (13/30). By trimester, gestational age was the most frequently reported application throughout; cardiac activity predominated in the first trimester, placental location in the mid-trimester, and fetal presentation in the third trimester. Methodological quality was generally high, with only one study receiving more than one domain rating of “No” or “Cannot Tell”. Conclusions: Antenatal POCUS in LMICs is being used primarily for focused obstetric assessments that can alter triage and referral. Evidence for broader applications, downstream clinical outcomes, and health-system integration remains limited. AI-enabled ultrasound could expand access, but clinical value will depend on training, governance, and referral capacity.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-26
DOI
https://doi.org/10.21203/rs.3.rs-9473580/v1
Primary Topic
Ultrasound in Clinical Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Antenatal point-of-care ultrasound in low- and middle-income countries: a systematic review

Aris T. Papageorghiou, Ashley Younger, Nia Wyn Roberts, Ankita Sharma et al.
Research Square
Ultrasound in Clinical Applications
preprint

Antenatal point-of-care ultrasound in low- and middle-income countries: a systematic review

Aris T. Papageorghiou, Ashley Younger, Nia Wyn Roberts, Ankita Sharma, Risa Miyazaki Sankar, Jane Hirst
preprint en

Abstract

Objective: To identify, evaluate, and synthesise reported applications of antenatal point-of-care ultrasound (POCUS) in low- and middle-income countries (LMICs). Design: Systematic review done in accordance with PRISMA 2020 and prospectively registered with PROSPERO (CRD42023410005). Methods: We searched EMBASE, CINAHL, The Cochrane Library, Global Health Library, MEDLINE, PubMed, and Web of Science Core Collection from inception to Dec 12, 2024. POCUS was defined as focused ultrasonographic imaging performed and interpreted in real time by the treating provider. We included peer-reviewed original studies reporting antenatal POCUS use in LMICs, with no restriction on study design, publication date, or language. Methodological quality was assessed with the Mixed Methods Appraisal Tool (MMAT), and reported applications were mapped by trimester usingInternational Society of Ultrasound in Obstetrics and Gynaecology (ISUOG) guidance to identify evidence gaps. Results: The search identified 6012 records, of which 30 studies were included. Studies were conducted in 17 countries, 68% in Africa. Most used quantitative designs; four were qualitative. Five studies evaluated machine learning or artificial intelligence for gestational age estimation, fetal presentation, or placental location. The most commonly reported POCUS applications were gestational age determination (23/30), placental location (20/30), fetal presentation (19/30), cardiac activity (17/30), biometry (15/30), fetal number (14/30), and amniotic fluid volume (13/30). By trimester, gestational age was the most frequently reported application throughout; cardiac activity predominated in the first trimester, placental location in the mid-trimester, and fetal presentation in the third trimester. Methodological quality was generally high, with only one study receiving more than one domain rating of “No” or “Cannot Tell”. Conclusions: Antenatal POCUS in LMICs is being used primarily for focused obstetric assessments that can alter triage and referral. Evidence for broader applications, downstream clinical outcomes, and health-system integration remains limited. AI-enabled ultrasound could expand access, but clinical value will depend on training, governance, and referral capacity.

Research Square
University of Oxford (GB)
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon