TPW-YOLO for microaneurysm detection with tile-phase consistency and workload-aware ranking

Detecting microaneurysms in retinal images requires accurate localization and careful candidate selec tion when the number of false positives is limited. TPW-YOLO combines visibility-gated tile-phase consistency learning with residual candidate ranking. During training, the detector aligns predictions for the same annotated lesion across shifted tiles. At inference, the ranker uses evidence from over lapping tiles in a single grid and leaves the candidate boxes unchanged. We evaluated the method on a common image-level partition of three public retinal image sources. On 67 internal test images, sensitivity reached 43.39% at four false positives per image on test-set score-threshold curves, exceed ing the matched random-shift baseline by 1.45 percentage points. Across three training seeds at the smaller detector scale, the descriptive mean gain was 4.75 percentage points, with a sample standard deviation of 2.84 points. Candidate ranking added 0.34–0.52 ms per image. Cross-tile supervision and candidate ranking improved lesion recovery at a fixed false-positive budget in this image-level benchmark.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-26
DOI
https://doi.org/10.21203/rs.3.rs-11635050/v1
Primary Topic
Retinal Imaging and Analysis
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

TPW-YOLO for microaneurysm detection with tile-phase consistency and workload-aware ranking

Chao Xu
Research Square
Retinal Imaging and Analysis
preprint

TPW-YOLO for microaneurysm detection with tile-phase consistency and workload-aware ranking

Chao Xu
preprint en

Abstract

Detecting microaneurysms in retinal images requires accurate localization and careful candidate selec tion when the number of false positives is limited. TPW-YOLO combines visibility-gated tile-phase consistency learning with residual candidate ranking. During training, the detector aligns predictions for the same annotated lesion across shifted tiles. At inference, the ranker uses evidence from over lapping tiles in a single grid and leaves the candidate boxes unchanged. We evaluated the method on a common image-level partition of three public retinal image sources. On 67 internal test images, sensitivity reached 43.39% at four false positives per image on test-set score-threshold curves, exceed ing the matched random-shift baseline by 1.45 percentage points. Across three training seeds at the smaller detector scale, the descriptive mean gain was 4.75 percentage points, with a sample standard deviation of 2.84 points. Candidate ranking added 0.34–0.52 ms per image. Cross-tile supervision and candidate ranking improved lesion recovery at a fixed false-positive budget in this image-level benchmark.

Research Square
Chengdu University of Technology (CN), The Engineering & Technical College of Chengdu University of Technology (CN)
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.