Continuous-flow magnesium electrocoagulation for nutrient recovery from Phosphate- limited domestic wastewater: effects of pH and applied current

The capability of continuous-flow magnesium electrocoagulation (EC-Mg) to simultaneously eliminate nutrients and potentially recover struvite from phosphate-limited domestic wastewater under different pH conditions and applied currents was investigated. The effects of pH levels between 7 and 9 and currents of 3, 5, and 10 A on the removal of phosphate and ammonium, reduction of total suspended solids (TSS), energy consumption, and precipitate characteristics were assessed. Phosphate removal was significantly affected by pH, with an optimal removal of 91.27 ± 4.15% at pH 8 and 5. In contrast, ammonium removal exhibited a different pattern, with the highest removal rate of 71.46% at pH 9 and 5–10 A, suggesting that ammonium removal was less sensitive to pH than phosphate removal was. Increasing the current from 3 to 5 A enhanced magnesium dissolution and nutrient removal; however, further increasing it to 10 A resulted in excessive energy use without improving nutrient removal. The TSS removal was approximately 96% at pH 8–10. Overall, pH 8 and 5 A were the most balanced operating conditions for continuous EC-Mg, offering effective nutrient removal, and reduced energy demand while maintaining the potential for nutrient recovery.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-26
DOI
https://doi.org/10.21203/rs.3.rs-11715713/v1
Primary Topic
Coagulation and Flocculation Studies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Continuous-flow magnesium electrocoagulation for nutrient recovery from Phosphate- limited domestic wastewater: effects of pH and applied current

Rachmad Ardhianto, Gani Purwiandono, Nurcahyo Iman Prakoso, Tatang Shabur Julianto et al.
Research Square
Coagulation and Flocculation Studies
preprint

Continuous-flow magnesium electrocoagulation for nutrient recovery from Phosphate- limited domestic wastewater: effects of pH and applied current

Rachmad Ardhianto, Gani Purwiandono, Nurcahyo Iman Prakoso, Tatang Shabur Julianto, Yulisya Zuriatni
preprint en

Abstract

The capability of continuous-flow magnesium electrocoagulation (EC-Mg) to simultaneously eliminate nutrients and potentially recover struvite from phosphate-limited domestic wastewater under different pH conditions and applied currents was investigated. The effects of pH levels between 7 and 9 and currents of 3, 5, and 10 A on the removal of phosphate and ammonium, reduction of total suspended solids (TSS), energy consumption, and precipitate characteristics were assessed. Phosphate removal was significantly affected by pH, with an optimal removal of 91.27 ± 4.15% at pH 8 and 5. In contrast, ammonium removal exhibited a different pattern, with the highest removal rate of 71.46% at pH 9 and 5–10 A, suggesting that ammonium removal was less sensitive to pH than phosphate removal was. Increasing the current from 3 to 5 A enhanced magnesium dissolution and nutrient removal; however, further increasing it to 10 A resulted in excessive energy use without improving nutrient removal. The TSS removal was approximately 96% at pH 8–10. Overall, pH 8 and 5 A were the most balanced operating conditions for continuous EC-Mg, offering effective nutrient removal, and reduced energy demand while maintaining the potential for nutrient recovery.

Research Square
Islamic University of Indonesia (ID), Institut Teknologi PLN (ID)
Coagulation and Flocculation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Continuous-flow magnesium electrocoagulation for nutrient recovery from Phosphate- limited domestic wastewater: effects of pH and applied current — Rachmad Ardhianto, Gani Purwiandono, et al. · Research Square (2026) | TGRS Research Map | TGRS