Generation of external surfaces for dental inlays using a nonrigid registration algorithm: an in vitro methodological study
Accurate reconstruction of missing tooth morphology from the remaining tooth structure remains a challenge in digital inlay design. This study applied an in-house-developed Procrustes analysis-nonrigid iterative closest point (PA-NICP) algorithm to generate dental inlay external surfaces and evaluated its performance in terms of morphological similarity and marginal adaptation. Forty three-dimensional digital models of mandibular right first molars with mild wear were obtained from the publicly available DCPR-GAN dataset. Twenty models were used for template construction, and the remaining 20 were used for algorithm evaluation. Six standardised inlay preparations were digitally simulated for each evaluation model: occlusal, bucco-occlusal, linguo-occlusal, mesio-occlusal, disto-occlusal and mesio-occluso-distal, yielding 120 simulated preparations in total. PA-NICP deformed the template to match each preparation and produced the corresponding inlay external surface. Template agreement with the remaining tooth surface was evaluated using root mean square (RMS) deviations after initial alignment and nonrigid registration. With the ground-truth data as the reference, morphological similarity and marginal adaptation were assessed using three-dimensional morphological deviation and three-dimensional curve deviation, respectively. Morphological and curve deviations were compared with their respective prespecified benchmarks using one-sided one-sample t tests or Wilcoxon signed-rank tests, depending on the data distribution. Exploratory comparisons among preparation types used Friedman tests followed by pairwise Wilcoxon signed-rank tests. Bonferroni correction was applied to adjust P values for multiple comparisons. PA-NICP produced external surfaces for all six types of mandibular right first-molar inlays. Mean RMS deviations in the non-defective region decreased after nonrigid registration across all six preparation types. The three-dimensional morphological deviations of all six types were significantly below the prespecified numerical benchmark of 0.150 mm (all adjusted P < 0.001). Their three-dimensional curve deviations were also significantly below the prespecified numerical benchmark of 0.050 mm (all adjusted P < 0.001). In exploratory comparisons among preparation types, after Bonferroni correction, only mesio-occluso-distal inlays showed greater morphological deviation than mesio-occlusal inlays, and only occlusal inlays showed greater digital curve deviation than mesio-occluso-distal inlays. PA-NICP generated inlay external surfaces with close morphological and margin-curve agreement at the digital-model level. These results were obtained using a single mean crown template and six simulated, idealised preparation types in mildly worn mandibular right first molars from a single dataset. The findings provide preliminary support for PA-NICP as a technical approach to digital inlay design. Its performance relative to existing inlay design methods remains to be established.
Authors
- Aonan Wen
- Xiaohui Zhang
- Yong Wang (ORCID: https://orcid.org/0000-0001-9696-2754)
- Wenbo Li (ORCID: https://orcid.org/0009-0004-8574-7046)
- Shenyao Shan
- Yijiao Zhao
- 白一亨
- Yongtao Yang
- Shuwei Guo
- Zixiang Gao
Institutions
- Peking University (CN)
- Capital Normal University (CN)
Publication Details
- Journal
- BMC Oral Health
- Published
- 2026-11-26
- DOI
- https://doi.org/10.1186/s12903-026-10442-y
- Primary Topic
- Dental materials and restorations
- Type
- article
- Field-Weighted Citation Impact
- 0.00