Energy, exergy, and convective heat transfer performance of a semi-tubular solar dryer: an experimental approach

This study experimentally investigates the thermal performance of a low-cost, direct semi-tubular solar dryer (STSD) under no-load conditions using natural and forced convection modes. The investigation provides a baseline understanding of the thermal behavior of the dryer before its application to agricultural product drying. Experimental measurements included ambient, inlet and outlet air temperatures, absorber plate temperature, drying chamber temperatures, relative humidity (RH), airflow velocity, and solar radiance (SR). During Natural Convection Drying (NCD) operation, the absorber surface attained its peak temperature of 82.6°C, exceeding the ambient temperature by nearly 47°C. The corresponding maximum temperature of the air at the dryer outlet was 66.8°C. Forced convection drying (FCD) was investigated at airflow velocities of 1.5, 2.0, and 2.5 m/s. Forced airflow improved heat removal and maintained more stable outlet air temperatures. The maximum hourly energy efficiencies were 52.74% and 66.7% under NCD and FCD, respectively, while the average exergy efficiencies ranged from 3.42% to 4.37%. The average convective heat-transfer coefficient (CHTC) increased from 10.59 W/m2·K under NCD to 17.50 W/m2·K under FCD at an airflow velocity of 2.5 m/s. Furthermore, a velocity-based empirical correlation h=9.20V0.734 was developed to estimate the CHTC. The correlation predictions closely matched the measured CHTC values, yielding an R2 of 0.994 and a mean absolute percentage error (MAPE) of 2.67%. The dryer can be fabricated at an estimated cost of approximately ₹9,300 (USD 99.5), indicating its potential for small-scale agricultural applications. These findings establish a thermal performance baseline for subsequent load-based drying investigations and further development of semi-tubular solar drying systems.

Authors

Institutions

Publication Details

Journal
Experimental Heat Transfer
Published
2026-11-25
DOI
https://doi.org/10.1080/08916152.2026.2768857
Primary Topic
Food Drying and Modeling
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Energy, exergy, and convective heat transfer performance of a semi-tubular solar dryer: an experimental approach

Sewan Das Patle, Satish Kumar Dewangan, Bhirendra Kumar
Experimental Heat Transfer
Food Drying and Modeling
article

Energy, exergy, and convective heat transfer performance of a semi-tubular solar dryer: an experimental approach

Sewan Das Patle, Satish Kumar Dewangan, Bhirendra Kumar
article en

Abstract

This study experimentally investigates the thermal performance of a low-cost, direct semi-tubular solar dryer (STSD) under no-load conditions using natural and forced convection modes. The investigation provides a baseline understanding of the thermal behavior of the dryer before its application to agricultural product drying. Experimental measurements included ambient, inlet and outlet air temperatures, absorber plate temperature, drying chamber temperatures, relative humidity (RH), airflow velocity, and solar radiance (SR). During Natural Convection Drying (NCD) operation, the absorber surface attained its peak temperature of 82.6°C, exceeding the ambient temperature by nearly 47°C. The corresponding maximum temperature of the air at the dryer outlet was 66.8°C. Forced convection drying (FCD) was investigated at airflow velocities of 1.5, 2.0, and 2.5 m/s. Forced airflow improved heat removal and maintained more stable outlet air temperatures. The maximum hourly energy efficiencies were 52.74% and 66.7% under NCD and FCD, respectively, while the average exergy efficiencies ranged from 3.42% to 4.37%. The average convective heat-transfer coefficient (CHTC) increased from 10.59 W/m2·K under NCD to 17.50 W/m2·K under FCD at an airflow velocity of 2.5 m/s. Furthermore, a velocity-based empirical correlation h=9.20V0.734 was developed to estimate the CHTC. The correlation predictions closely matched the measured CHTC values, yielding an R2 of 0.994 and a mean absolute percentage error (MAPE) of 2.67%. The dryer can be fabricated at an estimated cost of approximately ₹9,300 (USD 99.5), indicating its potential for small-scale agricultural applications. These findings establish a thermal performance baseline for subsequent load-based drying investigations and further development of semi-tubular solar drying systems.

Experimental Heat Transfer
National Institute of Technology Raipur (IN)
Food Drying and Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon