Mapping reserve-recoverable active power support from ultrafast charging stations with battery storage on unbalanced feeders

Ultrafast charging stations with battery storage can provide upward active-power support at the point of common coupling (PCC) while serving demand on unbalanced feeders. However, separately evaluated power, reserve and recovery limits may overstate deliverable support because battery replenishment and deferred charging compete for phase-specific headroom before fixed deadlines. This study formulates five PCC support boundaries within a common response-and-recovery model and combines joint-attainment certification with receding-horizon dispatch and nonlinear three-phase auditing. In 225 recovery-congested cases, the largest coupled contraction reduced a 1 MW candidate to 0.303 MW. A 480-point matched comparison yielded 0.225 MW mean held-out qualified support, compared with 0.183 MW for scenario chance control and 0.178 MW for box-robust control. The uncertainty-aware baselines provided stronger feeder-risk protection. These findings connect immediate support offers to achievable energy restoration and clarify the trade-off between recoverable support and network-risk protection.

Authors

Institutions

Publication Details

Journal
Electric Power Systems Research
Published
2026-11-26
DOI
https://doi.org/10.1016/j.epsr.2026.114557
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Mapping reserve-recoverable active power support from ultrafast charging stations with battery storage on unbalanced feeders

Haokang Jin, Hanwen Yu
Electric Power Systems Research
Optimal Power Flow Distribution
article

Mapping reserve-recoverable active power support from ultrafast charging stations with battery storage on unbalanced feeders

Haokang Jin, Hanwen Yu
article en

Abstract

Ultrafast charging stations with battery storage can provide upward active-power support at the point of common coupling (PCC) while serving demand on unbalanced feeders. However, separately evaluated power, reserve and recovery limits may overstate deliverable support because battery replenishment and deferred charging compete for phase-specific headroom before fixed deadlines. This study formulates five PCC support boundaries within a common response-and-recovery model and combines joint-attainment certification with receding-horizon dispatch and nonlinear three-phase auditing. In 225 recovery-congested cases, the largest coupled contraction reduced a 1 MW candidate to 0.303 MW. A 480-point matched comparison yielded 0.225 MW mean held-out qualified support, compared with 0.183 MW for scenario chance control and 0.178 MW for box-robust control. The uncertainty-aware baselines provided stronger feeder-risk protection. These findings connect immediate support offers to achievable energy restoration and clarify the trade-off between recoverable support and network-risk protection.

Electric Power Systems ResearchVol. 265
Politecnico di Milano (IT)
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Mapping reserve-recoverable active power support from ultrafast charging stations with battery storage on unbalanced feeders — Haokang Jin, Hanwen Yu · Electric Power Systems Research (2026) | TGRS Research Map | TGRS