Autonomous Bayesian Optimization in Electrochemical Aptamer Sensors

Electrochemical aptamer-based (EAB) sensors enable reagentless, real-time molecular detection, but their performance depends on square-wave voltammetry (SWV) parameters that are challenging to optimize due to the large number of possible parameter combinations. Conventional optimization studies in EAB sensing typically focus on sweeping the SWV frequency to identify operating conditions that maximize signal-on or signal-off responses to target molecules. However, this approach leaves the combined effects of frequency, amplitude, and step size largely unexplored. Furthermore, a single optimized parameter set is often applied across an entire batch of sensors without accounting for variations in electrode fabrication, morphology, and surface functionalization, each of which can influence the optimal operating conditions for individual sensors. Here, we implement an automated, closed-loop Bayesian optimization framework that tailors SWV frequency, amplitude, and step size to each individual sensor. Our approach efficiently explores the parameter space using a scoring function that rewards target-induced signal changes while penalizing measurement variability and noise. We demonstrate this framework using kanamycin-binding aptamers immobilized on planar and nanoporous gold electrodes and vancomycin-binding aptamers on nanoporous gold electrodes, identifying sensor-specific parameter combinations that optimize signal-on and signal-off responses. Notably, we find that amplitude and step size, in addition to frequency, influence the magnitude and direction of the target-induced response, potentially expanding the range of operating conditions available for kinetic differential measurement (KDM). We validate the optimized parameters through automated titrations, demonstrating improved sensing performance relative to a fixed reference SWV setting.

Authors

Institutions

Publication Details

Journal
ChemRxiv
Published
2026-11-26
DOI
https://doi.org/10.26434/chemrxiv.15012834/v1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Autonomous Bayesian Optimization in Electrochemical Aptamer Sensors

Michael Pedowitz, Jun‐Chau Chien, M. S. Ladabaum, Grigory Tikhomirov et al.
ChemRxiv
Advanced biosensing and bioanalysis techniques
preprint

Autonomous Bayesian Optimization in Electrochemical Aptamer Sensors

Michael Pedowitz, Jun‐Chau Chien, M. S. Ladabaum, Grigory Tikhomirov, K. Baris Oktay
preprint en

Abstract

Electrochemical aptamer-based (EAB) sensors enable reagentless, real-time molecular detection, but their performance depends on square-wave voltammetry (SWV) parameters that are challenging to optimize due to the large number of possible parameter combinations. Conventional optimization studies in EAB sensing typically focus on sweeping the SWV frequency to identify operating conditions that maximize signal-on or signal-off responses to target molecules. However, this approach leaves the combined effects of frequency, amplitude, and step size largely unexplored. Furthermore, a single optimized parameter set is often applied across an entire batch of sensors without accounting for variations in electrode fabrication, morphology, and surface functionalization, each of which can influence the optimal operating conditions for individual sensors. Here, we implement an automated, closed-loop Bayesian optimization framework that tailors SWV frequency, amplitude, and step size to each individual sensor. Our approach efficiently explores the parameter space using a scoring function that rewards target-induced signal changes while penalizing measurement variability and noise. We demonstrate this framework using kanamycin-binding aptamers immobilized on planar and nanoporous gold electrodes and vancomycin-binding aptamers on nanoporous gold electrodes, identifying sensor-specific parameter combinations that optimize signal-on and signal-off responses. Notably, we find that amplitude and step size, in addition to frequency, influence the magnitude and direction of the target-induced response, potentially expanding the range of operating conditions available for kinetic differential measurement (KDM). We validate the optimized parameters through automated titrations, demonstrating improved sensing performance relative to a fixed reference SWV setting.

ChemRxiv
Applied BioPhysics (United States) (US), University of California, Berkeley (US)
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon