Dissolving and Hydrogel-Forming Microneedles for Transdermal Delivery of Biologics: Formulation Parameters, Mechanical Strength, and Stability

Transdermal delivery of biologics such as proteins, peptides, vaccines, and nucleic acids is challenging because of their large molecular size, poor skin permeability, and susceptibility to degradation. Microneedle-based delivery systems are among newest pharmaceutical delivery systems that scientifically are formulated with components released on the attachment to the skin that minimizes the barrier of penetration upon the structure of the skin. Among the different microneedle platforms, dissolving microneedles (DMNs) and hydrogel-forming microneedles (HFMNs) have received considerable attention because of their potential for efficient, patient-friendly, and controlled drug delivery. This review focuses on the formulation strategies, mechanical strength, and stability considerations governing the performance of DMNs and HFMNs for transdermal delivery of biologics. Particular emphasis is placed on the selection and concentration of polymers, molecular weight, drug–polymer interactions, plasticizers, cross-linking agents, microneedle geometry, drug loading, and fabrication techniques. The role of mechanical strength in ensuring successful skin penetration without needle deformation or fracture is discussed, along with methods used to evaluate insertion efficiency and mechanical performance. Furthermore, the stability of biologics during formulation, fabrication, storage, and application is examined, considering factors such as temperature, moisture, polymer composition, and processing conditions. A comparative discussion of DMNs and HFMNs is presented in terms of drug-loading capacity, release behaviour, mechanical properties, stability, and potential for sustained delivery. The review also highlights current challenges, including dose limitations, preservation of biologic activity, standardization of mechanical testing, storage stability, sterilization, and scale-up. Overall, rational optimization of formulation and device characteristics is essential for developing mechanically robust and stable microneedle systems capable of translating biologic transdermal delivery from laboratory research to clinical applications.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-26
DOI
https://doi.org/10.5281/zenodo.24549238
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Dissolving and Hydrogel-Forming Microneedles for Transdermal Delivery of Biologics: Formulation Parameters, Mechanical Strength, and Stability

Aasha Makavana, Margaret Umi, Kintu Acram, Innocent Ayebembeire
Zenodo (CERN European Organization for Nuclear Research)
Advancements in Transdermal Drug Delivery
article

Dissolving and Hydrogel-Forming Microneedles for Transdermal Delivery of Biologics: Formulation Parameters, Mechanical Strength, and Stability

Aasha Makavana, Margaret Umi, Kintu Acram, Innocent Ayebembeire
article en

Abstract

Transdermal delivery of biologics such as proteins, peptides, vaccines, and nucleic acids is challenging because of their large molecular size, poor skin permeability, and susceptibility to degradation. Microneedle-based delivery systems are among newest pharmaceutical delivery systems that scientifically are formulated with components released on the attachment to the skin that minimizes the barrier of penetration upon the structure of the skin. Among the different microneedle platforms, dissolving microneedles (DMNs) and hydrogel-forming microneedles (HFMNs) have received considerable attention because of their potential for efficient, patient-friendly, and controlled drug delivery. This review focuses on the formulation strategies, mechanical strength, and stability considerations governing the performance of DMNs and HFMNs for transdermal delivery of biologics. Particular emphasis is placed on the selection and concentration of polymers, molecular weight, drug–polymer interactions, plasticizers, cross-linking agents, microneedle geometry, drug loading, and fabrication techniques. The role of mechanical strength in ensuring successful skin penetration without needle deformation or fracture is discussed, along with methods used to evaluate insertion efficiency and mechanical performance. Furthermore, the stability of biologics during formulation, fabrication, storage, and application is examined, considering factors such as temperature, moisture, polymer composition, and processing conditions. A comparative discussion of DMNs and HFMNs is presented in terms of drug-loading capacity, release behaviour, mechanical properties, stability, and potential for sustained delivery. The review also highlights current challenges, including dose limitations, preservation of biologic activity, standardization of mechanical testing, storage stability, sterilization, and scale-up. Overall, rational optimization of formulation and device characteristics is essential for developing mechanically robust and stable microneedle systems capable of translating biologic transdermal delivery from laboratory research to clinical applications.

Zenodo (CERN European Organization for Nuclear Research)
RK University (IN)
Advancements in Transdermal Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon