Finite element analysis of transverse three-Kirschner-wire fixation for distal radial diametaphyseal junction fractures in children

Objective To establish an idealized three-dimensional finite-element model based on forearm computed tomography data from an 11-year-old child. Using finite-element analysis (FEA), this study investigated the biomechanical performance of transverse three-Kirschner-wire fixation for pediatric distal radial diametaphyseal junction (DMP) fractures and compared it with conventional pinning techniques, so as to provide biomechanical evidence for further experimental and clinical application of this novel fixation strategy. Materials and methods Forearm CT datasets from a healthy 11-year-old boy and 2.0-mm Kirschner-wire parameters were imported into dedicated software. A standardized DMP transverse fracture model was constructed. Four finite-element assemblies were generated: transverse three-Kirschner-wire group, transverse two-Kirschner-wire group, parallel Kirschner-wire group, and crossed Kirschner-wire group. Six loading scenarios (30 N flexion, 30 N extension, 30 N compression, 30 N distraction, 1 N·m internal rotation, and 1 N·m external rotation) were simulated in ANSYS Workbench. Fracture-fragment relative displacement and Kirschner-wire stress distribution were compared across groups. Results Under all six loading conditions, the transverse three-wire group yielded the smallest maximum fracture-fragment displacement (0.888 mm, 0.888 mm, 0.496 mm, 0.497 mm, 0.000257 mm, 0.000257 mm, respectively). Under flexion, extension, internal-rotation and external-rotation loads, the parallel-wire group produced the lowest peak Kirschner-wire stress (456.8 MPa, 457.31 MPa, 0.639 MPa, 0.639 MPa). Under compression and distraction, the transverse three-wire group exhibited the lowest wire stress (241.83 MPa and 241.45 MPa). Conclusion In this single-sample idealized FEA simulation, transverse three-Kirschner-wire fixation produced the smallest fracture-end displacement, indicating superior fracture stability. Although this configuration only achieved the lowest peak wire stress under compression and distraction, stress contour plots demonstrated multi-point, relatively homogeneous stress dispersion, with absolute stress values that showed only limited differences from those of the other groups, indicating satisfactory fixation strength within an acceptable range. These are purely computer-simulated findings and cannot substitute clinical outcomes. Further cadaveric biomechanical tests and large-scale clinical investigations are required for validation.

Authors

Institutions

Publication Details

Journal
Frontiers in Pediatrics
Published
2026-11-26
DOI
https://doi.org/10.3389/fped.2026.1997983
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Finite element analysis of transverse three-Kirschner-wire fixation for distal radial diametaphyseal junction fractures in children

Zhiyi Zhou, Rui Ma, Xiaojun Chen, Jia Huang et al.
Frontiers in Pediatrics
Bone fractures and treatments
article

Finite element analysis of transverse three-Kirschner-wire fixation for distal radial diametaphyseal junction fractures in children

Zhiyi Zhou, Rui Ma, Xiaojun Chen, Jia Huang, Hao Liang, Zhihong Wan
article en

Abstract

Objective To establish an idealized three-dimensional finite-element model based on forearm computed tomography data from an 11-year-old child. Using finite-element analysis (FEA), this study investigated the biomechanical performance of transverse three-Kirschner-wire fixation for pediatric distal radial diametaphyseal junction (DMP) fractures and compared it with conventional pinning techniques, so as to provide biomechanical evidence for further experimental and clinical application of this novel fixation strategy. Materials and methods Forearm CT datasets from a healthy 11-year-old boy and 2.0-mm Kirschner-wire parameters were imported into dedicated software. A standardized DMP transverse fracture model was constructed. Four finite-element assemblies were generated: transverse three-Kirschner-wire group, transverse two-Kirschner-wire group, parallel Kirschner-wire group, and crossed Kirschner-wire group. Six loading scenarios (30 N flexion, 30 N extension, 30 N compression, 30 N distraction, 1 N·m internal rotation, and 1 N·m external rotation) were simulated in ANSYS Workbench. Fracture-fragment relative displacement and Kirschner-wire stress distribution were compared across groups. Results Under all six loading conditions, the transverse three-wire group yielded the smallest maximum fracture-fragment displacement (0.888 mm, 0.888 mm, 0.496 mm, 0.497 mm, 0.000257 mm, 0.000257 mm, respectively). Under flexion, extension, internal-rotation and external-rotation loads, the parallel-wire group produced the lowest peak Kirschner-wire stress (456.8 MPa, 457.31 MPa, 0.639 MPa, 0.639 MPa). Under compression and distraction, the transverse three-wire group exhibited the lowest wire stress (241.83 MPa and 241.45 MPa). Conclusion In this single-sample idealized FEA simulation, transverse three-Kirschner-wire fixation produced the smallest fracture-end displacement, indicating superior fracture stability. Although this configuration only achieved the lowest peak wire stress under compression and distraction, stress contour plots demonstrated multi-point, relatively homogeneous stress dispersion, with absolute stress values that showed only limited differences from those of the other groups, indicating satisfactory fixation strength within an acceptable range. These are purely computer-simulated findings and cannot substitute clinical outcomes. Further cadaveric biomechanical tests and large-scale clinical investigations are required for validation.

Frontiers in PediatricsVol. 14
Southwest Medical University (CN), Affiliated Hospital of Southwest Medical University (CN)
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon