Quantifying Water Balance Error in Bioretention Monitoring

Flow is a critical measurement parameter in stormwater control measure (SCM) performance monitoring studies evaluating hydrologic mitigation and pollutant loads; yet the accuracy of measurement is rarely quantified. This study quantified sources of hydrologic measurement uncertainty (including instrument accuracy and consistency, and weir calibration) and explored approaches to reducing error in field measurement through instrument configuration and prestorm equipment preparation. Full water balance data were obtained from four flow-through, concrete-lined bioretention planter SCMs presenting a well-defined field system with direct measurements of rainfall, influent, effluent, and media moisture levels during individual storm events. For each storm event, a water balance was considered “closed” when the differences between measured water flows and measured changes in media water storage from preevent to postevent were less than the combined measurement uncertainties. The inflow and outflow were measured with weir-pressure transducer combinations. The weir was calibrated in situ to determine the rating curve for each monitoring station. A first-order Taylor series model was used to propagate uncertainty from instruments and rating curves. This study found that the assigned depth from pressure transducer datum to the weir crest (i.e., the reference depth) had the greatest impact on generating accurate flow measurements, and raising the water level upstream of each weir to the weir crest before a storm improved water balance closure rates from 33% to 77% of events. Ensuring pressure transducers are completely submerged for the entire storm event and maintaining a consistent reference depth are recommended for monitoring SCMs.

Authors

Institutions

Publication Details

Journal
Journal of Sustainable Water in the Built Environment
Published
2026-11-26
DOI
https://doi.org/10.1061/jswbay.sweng-769
Primary Topic
Urban Stormwater Management Solutions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Quantifying Water Balance Error in Bioretention Monitoring

Michael Borst, Elizabeth A. Fassman-Beck, Kiera A. Nissen
Journal of Sustainable Water in the Built Environment
Urban Stormwater Management Solutions
article

Quantifying Water Balance Error in Bioretention Monitoring

Michael Borst, Elizabeth A. Fassman-Beck, Kiera A. Nissen
article en

Abstract

Flow is a critical measurement parameter in stormwater control measure (SCM) performance monitoring studies evaluating hydrologic mitigation and pollutant loads; yet the accuracy of measurement is rarely quantified. This study quantified sources of hydrologic measurement uncertainty (including instrument accuracy and consistency, and weir calibration) and explored approaches to reducing error in field measurement through instrument configuration and prestorm equipment preparation. Full water balance data were obtained from four flow-through, concrete-lined bioretention planter SCMs presenting a well-defined field system with direct measurements of rainfall, influent, effluent, and media moisture levels during individual storm events. For each storm event, a water balance was considered “closed” when the differences between measured water flows and measured changes in media water storage from preevent to postevent were less than the combined measurement uncertainties. The inflow and outflow were measured with weir-pressure transducer combinations. The weir was calibrated in situ to determine the rating curve for each monitoring station. A first-order Taylor series model was used to propagate uncertainty from instruments and rating curves. This study found that the assigned depth from pressure transducer datum to the weir crest (i.e., the reference depth) had the greatest impact on generating accurate flow measurements, and raising the water level upstream of each weir to the weir crest before a storm improved water balance closure rates from 33% to 77% of events. Ensuring pressure transducers are completely submerged for the entire storm event and maintaining a consistent reference depth are recommended for monitoring SCMs.

Journal of Sustainable Water in the Built EnvironmentVol. 13(1)
Stevens Institute of Technology (US), Southern California Coastal Water Research Project (US), Environmental Protection Agency (US), Environmental Protection Agency (IE), Oak Ridge Institute for Science and Education (US)
Urban Stormwater Management Solutions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon