VALIDATION OF HPLC METHOD FOR THE QUANTITATIVE DETERMINATION OF DICLAZURIL IN ANTICOCCIDIAL FEED ADDITIVE

The article presents the results of an independent validation evaluation of an analytical method for the quantitative determination of diclazuril in anticoccidial feed additive using high-performance liquid chromatography (HPLC). The relevance of the study is driven by the need to ensure metrological reliability and reproducibility of quality control methods for active pharmaceutical ingredients in feed products for veterinary medicine in accordance with the Laws of Ukraine and EMEA/CVMP/036/95 guidelines. Evaluation of metrological characteristics was carried out according to the main pharmacopoeial criteria: specificity (selectivity), linearity, accuracy (recovery rate), precision (inter-day reproducibility), and robustness in accordance with the requirements of the State Pharmacopoeia of Ukraine and VICH international guidelines. The study was performed on a liquid chromatographic system with diode-array detection using a certified reference standard and placebo matrix mixtures. The high specificity of the method was experimentally confirmed: excipients and carriers of the feed additive did not cause interference in the analytical signal zone of diclazuril. The linear dependence of the chromatographic peak area on the concentration of diclazuril was studied at five standard concentration levels ranging from 80% to 120% of the nominal value (16.0, 18.0, 20.0, 22.0, and 24.0 µg/mL). Statistical data processing established strict linearity with mean peak areas ranging from 4.9783 to 7.3145 mAU·min and a low relative standard deviation at each level (RSD = 0.15–0.50%). Precision and analyte recovery parameters indicate high stability and reproducibility of the analytical system. The relative standard deviation of inter-day precision at the nominal level over 3 analytical days was RSD = 1.30% (n = 9), and the average recovery rate of the analyte from the matrix equaled R = 96.95%, which fully meets the acceptance criteria for this group of compounds. The testing confirms high analytical reliability and suitability of the developed approach for routine quality control, laboratory certification, and commercial batch release of anticoccidial feed additives.

Authors

Institutions

Publication Details

Journal
Scientific and Technical Bulletin оf State Scientific Research Control Institute of Veterinary Medical Products and Fodder Additives аnd Institute of Animal Biology
Published
2026-11-26
DOI
https://doi.org/10.36359/scivp.2026-27-2.34
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

VALIDATION OF HPLC METHOD FOR THE QUANTITATIVE DETERMINATION OF DICLAZURIL IN ANTICOCCIDIAL FEED ADDITIVE

S. Melikyan, M.-M. Shymko, G. Mysko, N. Biront
Scientific and Technical Bulletin оf State Scientific Research Control Institute of Veterinary Medical Products and Fodder Additives аnd Institute of Animal Biology
Analytical Methods in Pharmaceuticals
article

VALIDATION OF HPLC METHOD FOR THE QUANTITATIVE DETERMINATION OF DICLAZURIL IN ANTICOCCIDIAL FEED ADDITIVE

S. Melikyan, M.-M. Shymko, G. Mysko, N. Biront
article en

Abstract

The article presents the results of an independent validation evaluation of an analytical method for the quantitative determination of diclazuril in anticoccidial feed additive using high-performance liquid chromatography (HPLC). The relevance of the study is driven by the need to ensure metrological reliability and reproducibility of quality control methods for active pharmaceutical ingredients in feed products for veterinary medicine in accordance with the Laws of Ukraine and EMEA/CVMP/036/95 guidelines. Evaluation of metrological characteristics was carried out according to the main pharmacopoeial criteria: specificity (selectivity), linearity, accuracy (recovery rate), precision (inter-day reproducibility), and robustness in accordance with the requirements of the State Pharmacopoeia of Ukraine and VICH international guidelines. The study was performed on a liquid chromatographic system with diode-array detection using a certified reference standard and placebo matrix mixtures. The high specificity of the method was experimentally confirmed: excipients and carriers of the feed additive did not cause interference in the analytical signal zone of diclazuril. The linear dependence of the chromatographic peak area on the concentration of diclazuril was studied at five standard concentration levels ranging from 80% to 120% of the nominal value (16.0, 18.0, 20.0, 22.0, and 24.0 µg/mL). Statistical data processing established strict linearity with mean peak areas ranging from 4.9783 to 7.3145 mAU·min and a low relative standard deviation at each level (RSD = 0.15–0.50%). Precision and analyte recovery parameters indicate high stability and reproducibility of the analytical system. The relative standard deviation of inter-day precision at the nominal level over 3 analytical days was RSD = 1.30% (n = 9), and the average recovery rate of the analyte from the matrix equaled R = 96.95%, which fully meets the acceptance criteria for this group of compounds. The testing confirms high analytical reliability and suitability of the developed approach for routine quality control, laboratory certification, and commercial batch release of anticoccidial feed additives.

Scientific and Technical Bulletin оf State Scientific Research Control Institute of Veterinary Medical Products and Fodder Additives аnd Institute of Animal BiologyVol. 27(2)
SCIVP of Veterinary Medicinal Products and Feed Additives (UA)
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon