Dual fidelity digital twin based adaptive estimation of states and parasitic parameters in buck converters

Reliable monitoring of slowly varying converter parameters is essential for digital twin based condition assessment of power electronic systems, operating under switching dynamics, thermal variations, parasitic effects, and measurement uncertainty. This paper proposes an innovation adaptive augmented extended Kalman filter (AAEKF) within a dual-fidelity digital twin framework for the joint estimation of electrical states and parasitic parameters in a buck converter. The augmented state incorporates the logarithms of the MOSFET on-state resistance, capacitor equivalent series resistance (ESR), and capacitance to ensure positive parameter estimates. A high fidelity switching model operating at a pulse-width modulation frequency of 100 kHz serves as the reference plant, while a reduced-order averaged model performs recursive state and parameter estimation. The proposed AAEKF employs a bounded, sensitivity weighted diagonal process noise covariance for parameter adaptation. Its performance is evaluated through 100 paired Monte Carlo trials, supplemented by dynamic disturbance and convergence analyses. In the Monte Carlo evaluation, the AAEKF achieves mean root mean square errors of 0.004630 for MOSFET on-state resistance, 0.001167 for ESR, and 13 μF for capacitance. The equally weighted aggregate improvement in normalized estimation error over the fixed EKF and UKF benchmarks is 0.593%, with a 95% paired-bootstrap confidence interval of 0.5386%–0.6481%, based on 5,000 resamples. Parameter-wise comparisons indicate that the improvement is not uniform across the estimated quantities; in particular, the capacitance improvement over the fixed EKF is marginal (0.169%). These findings indicate that the proposed adaptation provides modest, parameter dependent estimation benefits under the simulated conditions rather than universal performance superiority.

Authors

Institutions

Publication Details

Journal
Engineering Research Express
Published
2026-11-26
DOI
https://doi.org/10.1088/2631-8695/aec765
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Dual fidelity digital twin based adaptive estimation of states and parasitic parameters in buck converters

G. Ramya, BAARGAVEE V
Engineering Research Express
Advanced DC-DC Converters
article

Dual fidelity digital twin based adaptive estimation of states and parasitic parameters in buck converters

G. Ramya, BAARGAVEE V
article en

Abstract

Reliable monitoring of slowly varying converter parameters is essential for digital twin based condition assessment of power electronic systems, operating under switching dynamics, thermal variations, parasitic effects, and measurement uncertainty. This paper proposes an innovation adaptive augmented extended Kalman filter (AAEKF) within a dual-fidelity digital twin framework for the joint estimation of electrical states and parasitic parameters in a buck converter. The augmented state incorporates the logarithms of the MOSFET on-state resistance, capacitor equivalent series resistance (ESR), and capacitance to ensure positive parameter estimates. A high fidelity switching model operating at a pulse-width modulation frequency of 100 kHz serves as the reference plant, while a reduced-order averaged model performs recursive state and parameter estimation. The proposed AAEKF employs a bounded, sensitivity weighted diagonal process noise covariance for parameter adaptation. Its performance is evaluated through 100 paired Monte Carlo trials, supplemented by dynamic disturbance and convergence analyses. In the Monte Carlo evaluation, the AAEKF achieves mean root mean square errors of 0.004630 for MOSFET on-state resistance, 0.001167 for ESR, and 13 μF for capacitance. The equally weighted aggregate improvement in normalized estimation error over the fixed EKF and UKF benchmarks is 0.593%, with a 95% paired-bootstrap confidence interval of 0.5386%–0.6481%, based on 5,000 resamples. Parameter-wise comparisons indicate that the improvement is not uniform across the estimated quantities; in particular, the capacitance improvement over the fixed EKF is marginal (0.169%). These findings indicate that the proposed adaptation provides modest, parameter dependent estimation benefits under the simulated conditions rather than universal performance superiority.

Engineering Research Express
SRM Institute of Science and Technology (IN)
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon