Test-Time Adaptation in Optical Coherence Tomography Using Trajectory-Aligned Time-Independent Flow

Optical coherence tomography (OCT) is essential in ophthalmology, but inconsistent image quality especially in low-cost devices hinders automated analysis. To address this, we introduce a flow-matchingbased test-time adaptation method that generates high-quality surrogate images from noisy inputs. Typically, domain gaps between test and training data cause pixel distribution mismatches during the denoising process. We overcome this by matching the test image’s histogram to synthetic reference trajectories, successfully aligning the input with expected distributions. Additionally, we remove the network’s time conditioning to account for slight deviations in real-world noise distributions. Our approach achieves state-of-the-art performance in segmenting critical biomarkers for two stages of Age-related Macular Degeneration (AMD). Code is available here: https://github.com/Veit21/tta-flow.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-26
DOI
https://doi.org/10.5281/zenodo.24556361
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Test-Time Adaptation in Optical Coherence Tomography Using Trajectory-Aligned Time-Independent Flow

Ursula Margarethe Schmidt-Erfurth, Gregor Sebastian Reiter, Thomas Pinetz, Hrvoje Bogunović et al.
Zenodo (CERN European Organization for Nuclear Research)
Retinal Imaging and Analysis
article

Test-Time Adaptation in Optical Coherence Tomography Using Trajectory-Aligned Time-Independent Flow

Ursula Margarethe Schmidt-Erfurth, Gregor Sebastian Reiter, Thomas Pinetz, Hrvoje Bogunović, Veit Hucke
article en

Abstract

Optical coherence tomography (OCT) is essential in ophthalmology, but inconsistent image quality especially in low-cost devices hinders automated analysis. To address this, we introduce a flow-matchingbased test-time adaptation method that generates high-quality surrogate images from noisy inputs. Typically, domain gaps between test and training data cause pixel distribution mismatches during the denoising process. We overcome this by matching the test image’s histogram to synthetic reference trajectories, successfully aligning the input with expected distributions. Additionally, we remove the network’s time conditioning to account for slight deviations in real-world noise distributions. Our approach achieves state-of-the-art performance in segmenting critical biomarkers for two stages of Age-related Macular Degeneration (AMD). Code is available here: https://github.com/Veit21/tta-flow.

Zenodo (CERN European Organization for Nuclear Research)
Northwestern University (US), Österreichische Forschungsgemeinschaft (AT), Medical University of Vienna (AT)
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Test-Time Adaptation in Optical Coherence Tomography Using Trajectory-Aligned Time-Independent Flow — Ursula Margarethe Schmidt-Erfurth, Gregor Sebastian Reiter, et al. · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS