Calibration of digital cameras for remote measurements of luminance and illuminance of object surfaces

A method for calibrating commercial digital cameras for the remote measurement of the luminance and illuminance of object surfaces is presented in this paper. Traditional photometric methods based on sequential point measurements by luminance meters and lux meters are labour intensive, whereas the proposed approach makes it possible to create two-dimensional maps of the distribution of lighting parameters within the entire frame very quickly. The method is based on the application of unprocessed raw image data to ensure the linearity of the image sensor response and to avoid nonlinear transformations performed by the camera's built-in processor. The processing included conversion of the data into CIE 1931 X Y Z colour space, where the Y coordinate directly corresponds to the pixel luminance. A Canon EOS 1000D camera was used in this investigation. Calibration of this camera was carried out using semiconductor light sources with three colour temperatures (from 3053 to 7198 K) within the luminance range from 3.5 to 21.6 cd m −2. It is determined that in order to ensure the required accuracy, separate calibration models (in the form of the dependence of the Y coordinate on exposure) should be applied for each value of the aperture number. The resulting models demonstrated high approximation quality (R 2 >0.994). Verification on a diffuse-reflective surface showed an average deviation of 10.47 % for a sample of 21 525 control areas for first experimental dataset and an average deviation of 9.48 % for a sample of 2277 control areas for a second experimental dataset. Meanwhile, within the optimal range of the normalised signal (Y =0.1–0.4), the accuracy was higher when using models for each aperture value. The developed technology makes it possible to transform the common camera into an effective two-dimensional measuring tool for remote measurements of the object luminance and illuminance.

Authors

Institutions

Publication Details

Journal
Journal of sensors and sensor systems
Published
2026-11-26
DOI
https://doi.org/10.5194/jsss-15-209-2026
Primary Topic
Color Science and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Calibration of digital cameras for remote measurements of luminance and illuminance of object surfaces

Yaroslav Osadtsa, Валентин Судомир
Journal of sensors and sensor systems
Color Science and Applications
article

Calibration of digital cameras for remote measurements of luminance and illuminance of object surfaces

Yaroslav Osadtsa, Валентин Судомир
article en

Abstract

A method for calibrating commercial digital cameras for the remote measurement of the luminance and illuminance of object surfaces is presented in this paper. Traditional photometric methods based on sequential point measurements by luminance meters and lux meters are labour intensive, whereas the proposed approach makes it possible to create two-dimensional maps of the distribution of lighting parameters within the entire frame very quickly. The method is based on the application of unprocessed raw image data to ensure the linearity of the image sensor response and to avoid nonlinear transformations performed by the camera's built-in processor. The processing included conversion of the data into CIE 1931 X Y Z colour space, where the Y coordinate directly corresponds to the pixel luminance. A Canon EOS 1000D camera was used in this investigation. Calibration of this camera was carried out using semiconductor light sources with three colour temperatures (from 3053 to 7198 K) within the luminance range from 3.5 to 21.6 cd m −2. It is determined that in order to ensure the required accuracy, separate calibration models (in the form of the dependence of the Y coordinate on exposure) should be applied for each value of the aperture number. The resulting models demonstrated high approximation quality (R 2 >0.994). Verification on a diffuse-reflective surface showed an average deviation of 10.47 % for a sample of 21 525 control areas for first experimental dataset and an average deviation of 9.48 % for a sample of 2277 control areas for a second experimental dataset. Meanwhile, within the optimal range of the normalised signal (Y =0.1–0.4), the accuracy was higher when using models for each aperture value. The developed technology makes it possible to transform the common camera into an effective two-dimensional measuring tool for remote measurements of the object luminance and illuminance.

Journal of sensors and sensor systemsVol. 15(2)
Ternopil Ivan Pului National Technical University (UA)
Color Science and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Calibration of digital cameras for remote measurements of luminance and illuminance of object surfaces — Yaroslav Osadtsa, Валентин Судомир · Journal of sensors and sensor systems (2026) | TGRS Research Map | TGRS