Improved Precision of High b‐Value In Vivo Cardiac Diffusion Tensor Imaging on a Commercial Ultrahigh Performance Gradient MRI System

Cardiac diffusion tensor imaging (cDTI) enables non‐invasive assessment of myocardial microstructure, but clinical implementation remains limited by low signal‐to‐noise ratio (SNR) and the prolonged echo times associated with higher diffusion weighting. Ultrahigh‐performance gradients may enable higher b ‐values while maintaining clinically feasible acquisition times. This study compared cDTI precision at b = 500 and b = 1000 s/mm 2 on a commercially available 3 T MRI system equipped with ultrahigh‐performance gradients. Twenty healthy volunteers and six patients with cardiac amyloidosis (CA) underwent cDTI at b = 500 and b = 1000 s/mm 2 using identical acquisition parameters except for diffusion encoding strength and echo time. Mean diffusivity (MD), fractional anisotropy (FA), and helix angle transmurality (HAT) were calculated. SNR, geometric distortion, and measurement uncertainty were also assessed using bootstrap analysis. Paired statistical comparisons were performed between diffusion weightings in healthy volunteers. In healthy volunteers, b = 1000 s/mm 2 produced significantly lower MD (1.42 ± 0.05 vs. 1.51 ± 0.05 × 10 −3 mm 2 /s, p < 0.001) and FA (0.30 ± 0.02 vs. 0.32 ± 0.01, p < 0.001) and greater HAT magnitude (−0.86 ± 0.14 vs. −0.75° ± 0.18°/% transmural depth, p < 0.01) compared with b = 500 s/mm 2. Spatial variance was significantly reduced at b = 1000 s/mm 2 for MD, FA, and HAT. Uncertainty was reduced for MD, FA, and the first eigenvector. In CA, MD was higher and FA and HAT magnitude were lower than in healthy volunteers at both b ‐values. In sum, b = 1000 s/mm 2 cDTI demonstrated reduced spatial heterogeneity and lower measurement uncertainty compared with b = 500 s/mm 2 despite reduced SNR. Higher diffusion weighting may therefore improve the precision and microstructural specificity of cardiac diffusion measurements.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-11-25
DOI
https://doi.org/10.1002/nbm.70443
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Improved Precision of High b‐Value In Vivo Cardiac Diffusion Tensor Imaging on a Commercial Ultrahigh Performance Gradient MRI System

Arwa Younis, Christopher T Nguyen, Masafumi Sugawara, Danielle Kara et al.
NMR in Biomedicine
Advanced MRI Techniques and Applications
article

Improved Precision of High b‐Value In Vivo Cardiac Diffusion Tensor Imaging on a Commercial Ultrahigh Performance Gradient MRI System

Arwa Younis, Christopher T Nguyen, Masafumi Sugawara, Danielle Kara, Deborah H. Kwon, Xiaoming Bi, Hiroshi Nakagawa, Moses Cook, Oussama M. Wazni, Yuchi Liu, Shi Chen, Dingheng Mai, Thomas Garrett, Owen Lockwood
article en

Abstract

Cardiac diffusion tensor imaging (cDTI) enables non‐invasive assessment of myocardial microstructure, but clinical implementation remains limited by low signal‐to‐noise ratio (SNR) and the prolonged echo times associated with higher diffusion weighting. Ultrahigh‐performance gradients may enable higher b ‐values while maintaining clinically feasible acquisition times. This study compared cDTI precision at b = 500 and b = 1000 s/mm 2 on a commercially available 3 T MRI system equipped with ultrahigh‐performance gradients. Twenty healthy volunteers and six patients with cardiac amyloidosis (CA) underwent cDTI at b = 500 and b = 1000 s/mm 2 using identical acquisition parameters except for diffusion encoding strength and echo time. Mean diffusivity (MD), fractional anisotropy (FA), and helix angle transmurality (HAT) were calculated. SNR, geometric distortion, and measurement uncertainty were also assessed using bootstrap analysis. Paired statistical comparisons were performed between diffusion weightings in healthy volunteers. In healthy volunteers, b = 1000 s/mm 2 produced significantly lower MD (1.42 ± 0.05 vs. 1.51 ± 0.05 × 10 −3 mm 2 /s, p < 0.001) and FA (0.30 ± 0.02 vs. 0.32 ± 0.01, p < 0.001) and greater HAT magnitude (−0.86 ± 0.14 vs. −0.75° ± 0.18°/% transmural depth, p < 0.01) compared with b = 500 s/mm 2. Spatial variance was significantly reduced at b = 1000 s/mm 2 for MD, FA, and HAT. Uncertainty was reduced for MD, FA, and the first eigenvector. In CA, MD was higher and FA and HAT magnitude were lower than in healthy volunteers at both b ‐values. In sum, b = 1000 s/mm 2 cDTI demonstrated reduced spatial heterogeneity and lower measurement uncertainty compared with b = 500 s/mm 2 despite reduced SNR. Higher diffusion weighting may therefore improve the precision and microstructural specificity of cardiac diffusion measurements.

NMR in BiomedicineVol. 40(1)
Cleveland Clinic (US), Siemens Healthineers (United States) (US), Cleveland Clinic Research (US), Case Western Reserve University (US)
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon