Beyond Reduced-Order Models: Energy-Based Transient Stability Assessment of Current-Limited Grid-Forming Inverters

This repository provides the computational framework, simulation models, numerical results, and supporting research material associated with the study Beyond Reduced-Order Models: Energy-Based Transient Stability Assessment of Current-Limited Grid-Forming Inverters. The research investigates the applicability of reduced-order dynamic models and Lyapunov-based stability certificates to grid-forming (GFM) inverters operating under current-limiting conditions, with particular emphasis on structural model uncertainty, post-fault recovery dynamics, and critical clearing time (CCT) assessment. Research scope and methodology The computational framework combines nonlinear power system dynamics, energy-based stability analysis, electromagnetic transient (EMT) simulations, and non-parametric uncertainty quantification inspired by the Best Estimate Plus Uncertainty (BEPU) methodology used in nuclear safety analysis. The main research activities include: Implementation of reduced-order switched dynamic models of GFM inverters. State-dependent switched (SdS) Lyapunov energy functions and region-of-attraction estimation. Detailed electromagnetic transient models incorporating cascaded voltage and current controllers, digital control, LC filters, current saturation, and anti-windup strategies. Comparative assessment of circular current limiting and enhanced virtual impedance (EVI) limiting. Critical clearing time estimation under parametric and operating-condition uncertainties. Statistical tolerance limits using Wilks’ order statistics and exact binomial inference. Characterisation of structural model discrepancies through post-fault power mismatch and Lyapunov energy injection. Development and assessment of a composite EMT–energy-based procedure for transient stability evaluation. Investigation of model applicability as a function of short-circuit ratio (SCR), controller design, and network operating conditions. Computational efficiency assessment and independent statistical validation. Test systems Two power system configurations are investigated: A single grid-forming inverter connected to an infinite bus, evaluated across different grid strengths, impedance characteristics, operating conditions, and controller configurations. A modified WSCC 9-bus system incorporating two grid-forming inverters and one synchronous generator, enabling the investigation of multi-converter interactions, network contingencies, and local grid-strength effects. Computational environment and research material The research material includes Python scripts, MATLAB/Simulink and Simscape Electrical models, simulation parameters, uncertainty sampling configurations, numerical datasets, statistical calculations, and figure-generation routines. The simulations encompass reduced-order models, continuous dq representations, averaged EMT models, and selected switching-level PWM simulations. The repository is intended to support the reproducibility, independent verification, and further development of the numerical experiments and mathematical methodology presented in the associated manuscript. Scientific contribution and potential applications The central contribution is the characterisation of the loss of transferability of reduced-order stability guarantees to higher-fidelity models when internal converter dynamics become relevant during fault recovery. The framework provides a basis for further research into model-fidelity assessment, uncertainty-aware transient stability analysis, grid-forming converter design, renewable energy and battery energy storage system integration, and protection clearing-time requirements. The reported guarantees are conditional on the specified uncertainty distributions, controller families, model assumptions, and stability criteria. A general deterministic transfer of reduced-order Lyapunov certificates to EMT models is not claimed.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-26
DOI
https://doi.org/10.5281/zenodo.24562737
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Beyond Reduced-Order Models: Energy-Based Transient Stability Assessment of Current-Limited Grid-Forming Inverters

Ivan Emanuel Benitez Alonso
Zenodo (CERN European Organization for Nuclear Research)
Microgrid Control and Optimization
article

Beyond Reduced-Order Models: Energy-Based Transient Stability Assessment of Current-Limited Grid-Forming Inverters

Ivan Emanuel Benitez Alonso
article en

Abstract

This repository provides the computational framework, simulation models, numerical results, and supporting research material associated with the study Beyond Reduced-Order Models: Energy-Based Transient Stability Assessment of Current-Limited Grid-Forming Inverters. The research investigates the applicability of reduced-order dynamic models and Lyapunov-based stability certificates to grid-forming (GFM) inverters operating under current-limiting conditions, with particular emphasis on structural model uncertainty, post-fault recovery dynamics, and critical clearing time (CCT) assessment. Research scope and methodology The computational framework combines nonlinear power system dynamics, energy-based stability analysis, electromagnetic transient (EMT) simulations, and non-parametric uncertainty quantification inspired by the Best Estimate Plus Uncertainty (BEPU) methodology used in nuclear safety analysis. The main research activities include: Implementation of reduced-order switched dynamic models of GFM inverters. State-dependent switched (SdS) Lyapunov energy functions and region-of-attraction estimation. Detailed electromagnetic transient models incorporating cascaded voltage and current controllers, digital control, LC filters, current saturation, and anti-windup strategies. Comparative assessment of circular current limiting and enhanced virtual impedance (EVI) limiting. Critical clearing time estimation under parametric and operating-condition uncertainties. Statistical tolerance limits using Wilks’ order statistics and exact binomial inference. Characterisation of structural model discrepancies through post-fault power mismatch and Lyapunov energy injection. Development and assessment of a composite EMT–energy-based procedure for transient stability evaluation. Investigation of model applicability as a function of short-circuit ratio (SCR), controller design, and network operating conditions. Computational efficiency assessment and independent statistical validation. Test systems Two power system configurations are investigated: A single grid-forming inverter connected to an infinite bus, evaluated across different grid strengths, impedance characteristics, operating conditions, and controller configurations. A modified WSCC 9-bus system incorporating two grid-forming inverters and one synchronous generator, enabling the investigation of multi-converter interactions, network contingencies, and local grid-strength effects. Computational environment and research material The research material includes Python scripts, MATLAB/Simulink and Simscape Electrical models, simulation parameters, uncertainty sampling configurations, numerical datasets, statistical calculations, and figure-generation routines. The simulations encompass reduced-order models, continuous dq representations, averaged EMT models, and selected switching-level PWM simulations. The repository is intended to support the reproducibility, independent verification, and further development of the numerical experiments and mathematical methodology presented in the associated manuscript. Scientific contribution and potential applications The central contribution is the characterisation of the loss of transferability of reduced-order stability guarantees to higher-fidelity models when internal converter dynamics become relevant during fault recovery. The framework provides a basis for further research into model-fidelity assessment, uncertainty-aware transient stability analysis, grid-forming converter design, renewable energy and battery energy storage system integration, and protection clearing-time requirements. The reported guarantees are conditional on the specified uncertainty distributions, controller families, model assumptions, and stability criteria. A general deterministic transfer of reduced-order Lyapunov certificates to EMT models is not claimed.

Zenodo (CERN European Organization for Nuclear Research)
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon