Simultaneous Power Generation and kW-Level Heat Removal in Forced Convection Cooling by Redox Electrolyte Flow

Forced convection cooling (FCC) underpins our social infrastructure across a broad range of situations. The consumption of electricity inevitably generates unwanted heat, which must be removed to maintain heat-emitting objects below specific temperature limits. Because work can be extracted from a temperature difference, any FCC system can, in principle, generate power. If the power generated exceeds the pumping power required to send the coolant through a heat-emitting section, autonomous cooling is envisaged as an ultimate future FCC technology. Herein, to concretely study the feasibility of this concept, we created a novel liquid cooling thermocell that efficiently cools a kW-level heat source. The cell extracts electricity from the redox electrolyte flowing between interpenetrating fins of a hot electrode (a diamond−silver composite) and those of a graphite counter electrode. During the cooling of a 1−4.5 kW heat load while keeping the hot base temperature below 175 °Ctypical specifications of semiconductor power modulesthe system attains a gain (=power/pumping power needed to pass the coolant through the cell) of up to approximately 200. The power increases quadratically with the inter-electrode temperature difference, indicating the Ohmic character of the inter-electrode resistance. At a hot-base temperature of 175 °C and an inlet coolant temperature of 21 °C, which corresponds to the Carnot efficiency of 34%, an electric power of around 65−90 mW can be generated from the estimated inter-electrode heat flow of 13 W, converting approximately 0.5−0.7% of the inter-electrode heat flow to the electric power; this is lower than the Carnot efficiency, and hence the results do not violate the thermodynamics law. Furthermore, simulations show that maximizing the fin length is the most effective strategy for improving performance. These findings mark a historic milestone toward future autonomous liquid cooling that is expected to revolutionize FCC employed across a broad range of infrastructure.

Authors

Institutions

Publication Details

Journal
ACS Engineering Au
Published
2026-11-26
DOI
https://doi.org/10.1021/acsengineeringau.6c00092
Primary Topic
Advanced Thermoelectric Materials and Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Simultaneous Power Generation and kW-Level Heat Removal in Forced Convection Cooling by Redox Electrolyte Flow

Yoichi Murakami, Katsuhiko Kanaizuka, Xiaohan Wang, Riku Enomoto
ACS Engineering Au
Advanced Thermoelectric Materials and Devices
article

Simultaneous Power Generation and kW-Level Heat Removal in Forced Convection Cooling by Redox Electrolyte Flow

Yoichi Murakami, Katsuhiko Kanaizuka, Xiaohan Wang, Riku Enomoto
article en

Abstract

Forced convection cooling (FCC) underpins our social infrastructure across a broad range of situations. The consumption of electricity inevitably generates unwanted heat, which must be removed to maintain heat-emitting objects below specific temperature limits. Because work can be extracted from a temperature difference, any FCC system can, in principle, generate power. If the power generated exceeds the pumping power required to send the coolant through a heat-emitting section, autonomous cooling is envisaged as an ultimate future FCC technology. Herein, to concretely study the feasibility of this concept, we created a novel liquid cooling thermocell that efficiently cools a kW-level heat source. The cell extracts electricity from the redox electrolyte flowing between interpenetrating fins of a hot electrode (a diamond−silver composite) and those of a graphite counter electrode. During the cooling of a 1−4.5 kW heat load while keeping the hot base temperature below 175 °Ctypical specifications of semiconductor power modulesthe system attains a gain (=power/pumping power needed to pass the coolant through the cell) of up to approximately 200. The power increases quadratically with the inter-electrode temperature difference, indicating the Ohmic character of the inter-electrode resistance. At a hot-base temperature of 175 °C and an inlet coolant temperature of 21 °C, which corresponds to the Carnot efficiency of 34%, an electric power of around 65−90 mW can be generated from the estimated inter-electrode heat flow of 13 W, converting approximately 0.5−0.7% of the inter-electrode heat flow to the electric power; this is lower than the Carnot efficiency, and hence the results do not violate the thermodynamics law. Furthermore, simulations show that maximizing the fin length is the most effective strategy for improving performance. These findings mark a historic milestone toward future autonomous liquid cooling that is expected to revolutionize FCC employed across a broad range of infrastructure.

ACS Engineering Au
Yamagata University (JP), Institute of Science Tokyo (JP)
Advanced Thermoelectric Materials and Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon