Monte Carlo Study of Thermal Neutron and Gamma-Ray Conversion in a Composite Scintillator

This paper presents the results of a Monte Carlo simulation study of the ultimate performance of a composite scintillator for thermal neutron detection. The goal of the study was to determine these composite characteristics by varying its structural parameters: grain size, glass concentration, and total thickness. The simulations yielded the following: the maximum neutron conversion efficiency, the maximum composite thickness, and the minimum achievable γ-sensitivity. With a fixed neutron conversion efficiency of 0.7 for a 15 mm thick composite, γ-sensitivity can be achieved at a level of $$ \sim 7 \times {{10}^{{ - 8}}}$$, which is an order of magnitude lower than that of homogeneous glass scintillator NE 912 with a thickness of 1 mm.

Authors

Institutions

Publication Details

Journal
Physics of Particles and Nuclei Letters
Published
2026-11-26
DOI
https://doi.org/10.1134/s1547477126701037
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Monte Carlo Study of Thermal Neutron and Gamma-Ray Conversion in a Composite Scintillator

E. S. Kuzmin, I. Yu. Zimin, V. L. Malyshev
Physics of Particles and Nuclei Letters
Radiation Detection and Scintillator Technologies
article

Monte Carlo Study of Thermal Neutron and Gamma-Ray Conversion in a Composite Scintillator

E. S. Kuzmin, I. Yu. Zimin, V. L. Malyshev
article en

Abstract

This paper presents the results of a Monte Carlo simulation study of the ultimate performance of a composite scintillator for thermal neutron detection. The goal of the study was to determine these composite characteristics by varying its structural parameters: grain size, glass concentration, and total thickness. The simulations yielded the following: the maximum neutron conversion efficiency, the maximum composite thickness, and the minimum achievable γ-sensitivity. With a fixed neutron conversion efficiency of 0.7 for a 15 mm thick composite, γ-sensitivity can be achieved at a level of $$ \sim 7 \times {{10}^{{ - 8}}}$$, which is an order of magnitude lower than that of homogeneous glass scintillator NE 912 with a thickness of 1 mm.

Physics of Particles and Nuclei LettersVol. 23(6)
Joint Institute for Nuclear Research (RU)
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.