A Strategy for Suppressing Novel Harmonics of Distributed Photovoltaics in Distribution Networks Based on APF–LCLLC

In distribution networks with a high proportion of renewable energy and a high proportion of power electronics (High-RE-PE), harmonics generated by distributed photovoltaic (PV) systems and nonlinear loads coexist at multiple frequencies. Assessing the compensation performance of hybrid filtering strategies can inform the design of mitigation schemes for novel harmonics in distribution networks. Harmonic mitigation requires coordination between selective compensation of characteristic harmonics and attenuation of higher-frequency harmonics. An active power filter (APF) and an LCLLC passive filter are connected in series to form a hybrid branch in parallel with the load. The LCLLC filter attenuates higher-frequency harmonics, while the APF uses combined proportional–integral (PI) and quasi-proportional resonant (quasi-PR) control based on complementary decomposition of the tracking error. Quasi-PR regulates the error for the target characteristic harmonics, while PI regulates the residual error. Line and distribution transformer loss models are used to calculate equipment losses for different harmonic spectra. Compensation performance is compared across controller parameter settings. A MATLAB/Simulink model incorporating distributed PV generation and nonlinear loads is developed to verify system-level compensation performance. In the simulated case, APF–LCLLC compensation reduces the total harmonic distortion (THD) of the system current to 1.53%, considerably below 3.74% with APF compensation alone. The current waveform and harmonic spectrum are further improved. These results demonstrate effective compensation by the hybrid filtering structure in the examined case involving multiple harmonic sources. They offer a new approach to mitigating novel harmonics in distribution networks with distributed PV.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-11-26
DOI
https://doi.org/10.3390/pr14233806
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Strategy for Suppressing Novel Harmonics of Distributed Photovoltaics in Distribution Networks Based on APF–LCLLC

Yukun Su, Shengqi Zhou, Feng Zhou, Chao Yang et al.
Processes
Power Quality and Harmonics
article

A Strategy for Suppressing Novel Harmonics of Distributed Photovoltaics in Distribution Networks Based on APF–LCLLC

Yukun Su, Shengqi Zhou, Feng Zhou, Chao Yang, Shun Li, Jingui Lv, Shuhang Zhang
article en

Abstract

In distribution networks with a high proportion of renewable energy and a high proportion of power electronics (High-RE-PE), harmonics generated by distributed photovoltaic (PV) systems and nonlinear loads coexist at multiple frequencies. Assessing the compensation performance of hybrid filtering strategies can inform the design of mitigation schemes for novel harmonics in distribution networks. Harmonic mitigation requires coordination between selective compensation of characteristic harmonics and attenuation of higher-frequency harmonics. An active power filter (APF) and an LCLLC passive filter are connected in series to form a hybrid branch in parallel with the load. The LCLLC filter attenuates higher-frequency harmonics, while the APF uses combined proportional–integral (PI) and quasi-proportional resonant (quasi-PR) control based on complementary decomposition of the tracking error. Quasi-PR regulates the error for the target characteristic harmonics, while PI regulates the residual error. Line and distribution transformer loss models are used to calculate equipment losses for different harmonic spectra. Compensation performance is compared across controller parameter settings. A MATLAB/Simulink model incorporating distributed PV generation and nonlinear loads is developed to verify system-level compensation performance. In the simulated case, APF–LCLLC compensation reduces the total harmonic distortion (THD) of the system current to 1.53%, considerably below 3.74% with APF compensation alone. The current waveform and harmonic spectrum are further improved. These results demonstrate effective compensation by the hybrid filtering structure in the examined case involving multiple harmonic sources. They offer a new approach to mitigating novel harmonics in distribution networks with distributed PV.

ProcessesVol. 14(23)
State Grid Corporation of China (China) (CN), Hisense (China) (CN), Shanghai Electric (China) (CN), State Grid Shandong Electric Power Company (China) (CN), Shandong University of Science and Technology (CN)
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon