Outcomes of patients undergoing enucleation with and without postoperative conformer placement: a 12-year review

Introduction Conformer placement after enucleation is widely considered standard practice. However, evidence directly evaluating outcomes without conformer use is limited. This study compared post-enucleation outcomes in patients managed with and without conformers, hypothesizing that non-conformer use does not significantly increase socket morbidity.Methods This retrospective cohort study reviewed adult patients who underwent enucleation at a single institution from 2012–2024. Records were reviewed for demographics, indication for surgery, implant characteristics, conformer placement, and postoperative outcomes. Outcomes included clinically evident socket contracture, symblepharon, prosthetic motility, implant exposure, secondary socket surgery, prosthesis nonuse at follow-up, and postoperative telephone encounters. Fisher exact testing was used for categorical comparisons.Results Of 248 charts reviewed, 163 patients met inclusion criteria. Mean age was 59.6 years; 78 patients were male and 85 were female. Forty-two patients received a conformer and 121 did not. The duration of postoperative follow-up ranged from 2 to 112 months with a mean follow-up of 16.8 months in the non-conformer group and 18.1 months in the conformer group. Socket contracture occurred in 7.1% versus 3.3% of patients, respectively (p = 0.375); symblepharon in 4.8% versus 3.3% (p = 0.648); and limited prosthetic motility in 7.1% versus 3.3% (p = 0.375). Implant exposure occurred in 2.4% versus 3.3%. Secondary socket surgery occurred in 7.1% versus 8.3% (p > 0.99), and prosthesis nonuse at the last follow-up occurred in 16.7% versus 14.0% (p = 0.65). Telephone encounter frequency was similar between groups.Conclusions Selective omission of a postoperative conformer was not associated with higher rates of clinically meaningful socket complications. These findings support individualized conformer use after enucleation.

Authors

Institutions

Publication Details

Journal
Orbit
Published
2026-11-25
DOI
https://doi.org/10.1080/01676830.2026.2769006
Primary Topic
Ocular Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Outcomes of patients undergoing enucleation with and without postoperative conformer placement: a 12-year review

Michael T. Yen, Vandana Venkatesh, May Ameri, George A. Villatoro
1 links
Orbit
Ocular Disorders and Treatments
article

Outcomes of patients undergoing enucleation with and without postoperative conformer placement: a 12-year review

Michael T. Yen, Vandana Venkatesh, May Ameri, George A. Villatoro
article en

Abstract

Introduction Conformer placement after enucleation is widely considered standard practice. However, evidence directly evaluating outcomes without conformer use is limited. This study compared post-enucleation outcomes in patients managed with and without conformers, hypothesizing that non-conformer use does not significantly increase socket morbidity.Methods This retrospective cohort study reviewed adult patients who underwent enucleation at a single institution from 2012–2024. Records were reviewed for demographics, indication for surgery, implant characteristics, conformer placement, and postoperative outcomes. Outcomes included clinically evident socket contracture, symblepharon, prosthetic motility, implant exposure, secondary socket surgery, prosthesis nonuse at follow-up, and postoperative telephone encounters. Fisher exact testing was used for categorical comparisons.Results Of 248 charts reviewed, 163 patients met inclusion criteria. Mean age was 59.6 years; 78 patients were male and 85 were female. Forty-two patients received a conformer and 121 did not. The duration of postoperative follow-up ranged from 2 to 112 months with a mean follow-up of 16.8 months in the non-conformer group and 18.1 months in the conformer group. Socket contracture occurred in 7.1% versus 3.3% of patients, respectively (p = 0.375); symblepharon in 4.8% versus 3.3% (p = 0.648); and limited prosthetic motility in 7.1% versus 3.3% (p = 0.375). Implant exposure occurred in 2.4% versus 3.3%. Secondary socket surgery occurred in 7.1% versus 8.3% (p > 0.99), and prosthesis nonuse at the last follow-up occurred in 16.7% versus 14.0% (p = 0.65). Telephone encounter frequency was similar between groups.Conclusions Selective omission of a postoperative conformer was not associated with higher rates of clinically meaningful socket complications. These findings support individualized conformer use after enucleation.

Orbit
Baylor College of Medicine (US)
Good health and well-being
Ocular Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon