THERMAL-HYDRAULIC DESIGN OF THE NATURALLY VENTILATED AIR GAP BEHIND FACADE-INTEGRATED PHOTOVOLTAIC MODULES: A COUPLED STEADY-STATE MODEL FOR THE CLIMATE OF FERGANA
Facade-integrated photovoltaic (BIPV) modules mounted directly on an insulated wall operate at high temperatures; a naturally ventilated air gap is a simple way to cool them. This study determined how the gap width should be chosen for a given gap height under the climatic conditions of Fergana. A coupled steady-state model was developed that combines the energy balances of the module and the wall, an analytical air-temperature profile along the gap and a buoyancy–pressure-loss balance for the draught, with heat-transfer and loss coefficients calibrated against CFD. Gap widths of 8–300 mm and heights of 1–12 m were analysed for a winter (900 W/m², 5 °C) and a summer (500 W/m², 35 °C) design point derived from a typical meteorological year. For every height the module temperature had a distinct minimum; for these design conditions the near-optimal gap width (within 0.5 K of the minimum) was 14–20 mm for 1.5 m, 30–70 mm for 3 m, 40–85 mm for 6 m and 60–130 mm for 12 m. At 900 W/m² a 50 mm gap of 3 m height lowered the module temperature by 11.7 K and increased the electrical output by 4.6 % compared with a glued module.
Authors
- A. A. Kuchkarov (ORCID: https://orcid.org/0000-0002-1993-700X)
- Wencheng Li
- Zafarjon Odiljon ugli Obidjonov
Institutions
- North China University of Technology (CN)
- Kurgan State University (RU)
- Ferghana Polytechnical Institute (UZ)
- Ferghana State University (UZ)
- Fergana State Technical University (UZ)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-25
- DOI
- https://doi.org/10.5281/zenodo.24525733
- Primary Topic
- Solar Thermal and Photovoltaic Systems
- Type
- article
- Field-Weighted Citation Impact
- 0.00