A battery reliability pipeline based on Arrhenius degradation model

This article proposes an integrated pipeline for battery reliability prediction combining electrothermal modeling, Arrhenius and Tafel kinetic formulations, and stochastic Monte Carlo analysis. Unlike conventional approaches, the methodology simultaneously incorporates temperature, operating voltage, electrochemical dynamics, and operational variability, enabling physically grounded lifetime estimation under realistic usage conditions. The framework links mission profiles, internal losses, thermal evolution, and electrochemical aging, quantifying accumulated damage through the Palmgren–Miner rule and estimating the B 10 lifetime using the Lognormal distribution. The degradation formulations are adapted to directly available variables, including voltage, current, and temperature, reducing dependence on cell overpotential measurements and facilitating application to batteries, large packs, and storage systems under real operating conditions. Results show that reliability is strongly affected by the operational profile. In the default scenario, the analyzed pack achieved a B 10 lifetime of 9.78 years. Reducing the charge rate to 0.5C increased this value to 19.56 years, whereas operation at 2C reduced it to 4.87 years. Across all evaluated scenarios, the B 10 lifetime ranged from 19.59 to 3.12 years. The State of Accumulated Damage (SAD) is also introduced as a reliability-oriented state variable representing the fraction of lifetime consumed throughout operation. Comparison with a consolidated calendar-aging approach showed satisfactory agreement under equivalent conditions, with absolute percentage variations from 1.37% to 5.12%, and coherent behavior under dynamic profiles. The proposed methodology therefore shows potential for Battery Management System (BMS) implementation, enabling real-time degradation estimation and supporting control and maintenance strategies that improve battery reliability, safety, and service life across diverse applications and changing operating environments.

Authors

Institutions

Publication Details

Journal
Journal of Energy Storage
Published
2026-11-25
DOI
https://doi.org/10.1016/j.est.2026.125795
Primary Topic
Battery Modeling and Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A battery reliability pipeline based on Arrhenius degradation model

Tárcio André dos Santos Barros, Marcelo Vinícius De Paula, Andressa Mara Menezes Alexandre, Paulo Soares Filho
1 links
Journal of Energy Storage
Battery Modeling and Management
article

A battery reliability pipeline based on Arrhenius degradation model

Tárcio André dos Santos Barros, Marcelo Vinícius De Paula, Andressa Mara Menezes Alexandre, Paulo Soares Filho
article en

Abstract

This article proposes an integrated pipeline for battery reliability prediction combining electrothermal modeling, Arrhenius and Tafel kinetic formulations, and stochastic Monte Carlo analysis. Unlike conventional approaches, the methodology simultaneously incorporates temperature, operating voltage, electrochemical dynamics, and operational variability, enabling physically grounded lifetime estimation under realistic usage conditions. The framework links mission profiles, internal losses, thermal evolution, and electrochemical aging, quantifying accumulated damage through the Palmgren–Miner rule and estimating the B 10 lifetime using the Lognormal distribution. The degradation formulations are adapted to directly available variables, including voltage, current, and temperature, reducing dependence on cell overpotential measurements and facilitating application to batteries, large packs, and storage systems under real operating conditions. Results show that reliability is strongly affected by the operational profile. In the default scenario, the analyzed pack achieved a B 10 lifetime of 9.78 years. Reducing the charge rate to 0.5C increased this value to 19.56 years, whereas operation at 2C reduced it to 4.87 years. Across all evaluated scenarios, the B 10 lifetime ranged from 19.59 to 3.12 years. The State of Accumulated Damage (SAD) is also introduced as a reliability-oriented state variable representing the fraction of lifetime consumed throughout operation. Comparison with a consolidated calendar-aging approach showed satisfactory agreement under equivalent conditions, with absolute percentage variations from 1.37% to 5.12%, and coherent behavior under dynamic profiles. The proposed methodology therefore shows potential for Battery Management System (BMS) implementation, enabling real-time degradation estimation and supporting control and maintenance strategies that improve battery reliability, safety, and service life across diverse applications and changing operating environments.

Journal of Energy StorageVol. 185
Universidade Estadual de Campinas (UNICAMP) (BR)
Fundação de Amparo à Pesquisa do Estado de São Paulo, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico
Affordable and clean energy
Battery Modeling and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon