Assessing lymphatic drainage of the colon and rectum by single-photon emission computerised tomography: a feasibility study in patients undergoing standard-of-care colonoscopy

Objective The splenic flexure (SF) has variable lymphatic drainage due to its heterogeneous vascular supply, contributing to uncertainty regarding optimal oncological resection. This study evaluated the feasibility and safety of in vivo lymphatic mapping of the SF and rectum using endoscopic submucosal Technetium-99 m (Tc-99 m) radiocolloid injection followed by planar lymphoscintigraphy and single-photon emission computed tomography (SPECT), and assessed the reproducibility of identifying a dominant lymphatic pedicle (DLP) consistently. Methods A prospective pilot study was conducted at Concord Repatriation General Hospital, Sydney (2022–2023), in patients undergoing standard-of-care colonoscopy who had macroscopically normal colorectal anatomy. Submucosal radiocolloid injections were administered at the SF (n = 10), upper rectum (n = 5) or lower rectum with direct digital massage (n = 5). Tc-99 m Nanoscan or Tc-99 m antimony trisulfide (40MBq in 1.3 mL, with methylene blue) was used. Serial planar lymphoscintigraphy was performed at 1, 2, 4 and 24 h, with SPECT at 1, 2 and 4 h and additional delayed imaging at 24 and/or 48 h. Imaging was assessed for tracer dispersion, nodal uptake and DLP identification. Results Submucosal injection was technically successful in all 20 patients, without extravasation or adverse events occurred at 1-, 7-, or 30-day follow-up. No consistent DLP was demonstrated following SF injections on planar or SPECT imaging, including on delayed imaging. Specifically, eight SF patients showed only focal or dispersed tracer activity and only two showed a DLP (i.e., inferior mesenteric artery [IMA]). Similarly, no lymphatic drainage or nodal uptake was demonstrated in any of the five upper rectal patients intended to be ‘positive controls’. In contrast, all patients who underwent lower rectal injections demonstrated lymphatic drainage following direct finger massage; with a DLP identified in three patients (60%), and LN activity observed in all five patients (100%) involving pelvic sidewall, presacral, iliac, and para-aortic regions. SPECT improved anatomical localisation compared with planar imaging alone. Conclusions Submucosal Tc-99 m radiocolloid injection combined with planar lymphoscintigraphy and SPECT is technically feasible and safe for colorectal lymphatic mapping. However, the current protocol does not reliably identify a DLP, even within the anatomically more predictable upper rectum, thereby limiting its immediate clinical applicability. Further technical refinement and independent validation are required before this approach can be considered suitable for routine preoperative colorectal lymphatic mapping. Trial registration Australian New Zealand Clinical Trials Registry (ANZCTR) ID – ACTRN12622001439730 (Date of Registration: 10/11/2022); Therapeutic Goods Administration Clinical Trial Notification (TGA CTN) ID:7FX9YJ99.

Authors

Institutions

Publication Details

Journal
Frontiers in Nuclear Medicine
Published
2026-11-25
DOI
https://doi.org/10.3389/fnume.2026.1962601
Primary Topic
Colorectal Cancer Surgical Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Assessing lymphatic drainage of the colon and rectum by single-photon emission computerised tomography: a feasibility study in patients undergoing standard-of-care colonoscopy

Grace Yung, Kheng‐Seong Ng, Matthew J. F. X. Rickard, Krishanth Naidu et al.
Frontiers in Nuclear Medicine
Colorectal Cancer Surgical Treatments
article

Assessing lymphatic drainage of the colon and rectum by single-photon emission computerised tomography: a feasibility study in patients undergoing standard-of-care colonoscopy

Grace Yung, Kheng‐Seong Ng, Matthew J. F. X. Rickard, Krishanth Naidu, Roberto R Russo, Nicholas Forwood
article en

Abstract

Objective The splenic flexure (SF) has variable lymphatic drainage due to its heterogeneous vascular supply, contributing to uncertainty regarding optimal oncological resection. This study evaluated the feasibility and safety of in vivo lymphatic mapping of the SF and rectum using endoscopic submucosal Technetium-99 m (Tc-99 m) radiocolloid injection followed by planar lymphoscintigraphy and single-photon emission computed tomography (SPECT), and assessed the reproducibility of identifying a dominant lymphatic pedicle (DLP) consistently. Methods A prospective pilot study was conducted at Concord Repatriation General Hospital, Sydney (2022–2023), in patients undergoing standard-of-care colonoscopy who had macroscopically normal colorectal anatomy. Submucosal radiocolloid injections were administered at the SF (n = 10), upper rectum (n = 5) or lower rectum with direct digital massage (n = 5). Tc-99 m Nanoscan or Tc-99 m antimony trisulfide (40MBq in 1.3 mL, with methylene blue) was used. Serial planar lymphoscintigraphy was performed at 1, 2, 4 and 24 h, with SPECT at 1, 2 and 4 h and additional delayed imaging at 24 and/or 48 h. Imaging was assessed for tracer dispersion, nodal uptake and DLP identification. Results Submucosal injection was technically successful in all 20 patients, without extravasation or adverse events occurred at 1-, 7-, or 30-day follow-up. No consistent DLP was demonstrated following SF injections on planar or SPECT imaging, including on delayed imaging. Specifically, eight SF patients showed only focal or dispersed tracer activity and only two showed a DLP (i.e., inferior mesenteric artery [IMA]). Similarly, no lymphatic drainage or nodal uptake was demonstrated in any of the five upper rectal patients intended to be ‘positive controls’. In contrast, all patients who underwent lower rectal injections demonstrated lymphatic drainage following direct finger massage; with a DLP identified in three patients (60%), and LN activity observed in all five patients (100%) involving pelvic sidewall, presacral, iliac, and para-aortic regions. SPECT improved anatomical localisation compared with planar imaging alone. Conclusions Submucosal Tc-99 m radiocolloid injection combined with planar lymphoscintigraphy and SPECT is technically feasible and safe for colorectal lymphatic mapping. However, the current protocol does not reliably identify a DLP, even within the anatomically more predictable upper rectum, thereby limiting its immediate clinical applicability. Further technical refinement and independent validation are required before this approach can be considered suitable for routine preoperative colorectal lymphatic mapping. Trial registration Australian New Zealand Clinical Trials Registry (ANZCTR) ID – ACTRN12622001439730 (Date of Registration: 10/11/2022); Therapeutic Goods Administration Clinical Trial Notification (TGA CTN) ID:7FX9YJ99.

Frontiers in Nuclear MedicineVol. 6
The University of Sydney (AU), Concord Hospital (US), Concord Repatriation General Hospital (AU), Canberra Hospital (AU)
Medtronic, Royal Australasian College of Surgeons, University of Sydney, Colorectal Surgical Society of Australia and New Zealand
Good health and well-being
Colorectal Cancer Surgical Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon