Damping Ratio and Convergence Rate Analysis for Inverter-Based Power Systems via Root Locus

As more renewables enter the grid, it becomes insufficient to rely solely on the center of inertia frequency to analyze the transient performance, especially for oscillation behaviors. Motivated by this, we study the transient frequency performance of inverter-based power systems. Two key performance criteria are considered: the damping ratio and the convergence rate, which are determined by the angles and the real parts of the closed-loop poles, respectively. By decomposing the network system into a set of scalar feedback systems, we show that the closed-loop poles can be analyzed using the root locus of a scalar feedback system as the gain varies from the smallest nonzero eigenvalue to the largest eigenvalue of the scaled Laplacian matrix of the interconnection network. Based on this, we derive sufficient conditions that ensure desired damping and convergence performance. Our analysis shows that the worst-case damping ratio and convergence rate occur when the gain equals the largest and the smallest nonzero eigenvalues of the scaled Laplacian, respectively. This result significantly simplifies the performance assessment. We further provide guidelines for tuning the inverter parameter. Numerical simulations are included to illustrate and validate the proposed approach.

Authors

Publication Details

Journal
arXiv
Published
2026-11-24
DOI
https://doi.org/10.48550/arxiv.2611.32111
Primary Topic
Microgrid Control and Optimization
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Damping Ratio and Convergence Rate Analysis for Inverter-Based Power Systems via Root Locus

Shinji Hara, Dan Wang, Yan Jiang, Wei Chen
arXiv
Microgrid Control and Optimization
preprint

Damping Ratio and Convergence Rate Analysis for Inverter-Based Power Systems via Root Locus

Shinji Hara, Dan Wang, Yan Jiang, Wei Chen
preprint en

Abstract

As more renewables enter the grid, it becomes insufficient to rely solely on the center of inertia frequency to analyze the transient performance, especially for oscillation behaviors. Motivated by this, we study the transient frequency performance of inverter-based power systems. Two key performance criteria are considered: the damping ratio and the convergence rate, which are determined by the angles and the real parts of the closed-loop poles, respectively. By decomposing the network system into a set of scalar feedback systems, we show that the closed-loop poles can be analyzed using the root locus of a scalar feedback system as the gain varies from the smallest nonzero eigenvalue to the largest eigenvalue of the scaled Laplacian matrix of the interconnection network. Based on this, we derive sufficient conditions that ensure desired damping and convergence performance. Our analysis shows that the worst-case damping ratio and convergence rate occur when the gain equals the largest and the smallest nonzero eigenvalues of the scaled Laplacian, respectively. This result significantly simplifies the performance assessment. We further provide guidelines for tuning the inverter parameter. Numerical simulations are included to illustrate and validate the proposed approach.

arXiv
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon