Harm from indoor air contaminants in an office building

Indoor air quality in offices is usually interpreted through benchmark exceedance, although exceedance alone does not quantify health burden across a multi-contaminant mixture. This study applies benchmark comparison (HQ), regulated harm (RH), and disability-adjusted life-year (DALY)-based harm assessment to measured indoor air contaminants in a monitored public office building in Bolzano, Italy. In the primary benchmark assessment, propanal was the only contaminant with HQ > 1, while benchmark choice altered the ordering of contaminants below the exceedance threshold. When measured concentrations were translated into DALY-based harm, PM 2.5, formaldehyde, and derived PM 10–2.5 were identified as prospective contaminants of concern within the quantified set and together accounted for 99.3% of mean total harm among 15 contaminants with available harm inputs. Benchmark comparison, regulated harm, and DALY-based harm provided complementary interpretations of the monitored mixture. HQ quantified proximity to selected health-based benchmarks, RH the model-based harm implied at those benchmark concentrations, and DALY-based harm the model-based impact at the measured concentrations. Their joint use links benchmark screening with health-based prioritisation of site-specific office measurements.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-25
DOI
https://doi.org/10.1038/s41598-026-79785-4
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Harm from indoor air contaminants in an office building

Irene Lara-Ibeas, Chiara Nomellini, Francesco Babich, Giulia Torriani et al.
2 links
Scientific Reports
Indoor Air Quality and Microbial Exposure
article

Harm from indoor air contaminants in an office building

Irene Lara-Ibeas, Chiara Nomellini, Francesco Babich, Giulia Torriani, Giobertti Morantes
article en

Abstract

Indoor air quality in offices is usually interpreted through benchmark exceedance, although exceedance alone does not quantify health burden across a multi-contaminant mixture. This study applies benchmark comparison (HQ), regulated harm (RH), and disability-adjusted life-year (DALY)-based harm assessment to measured indoor air contaminants in a monitored public office building in Bolzano, Italy. In the primary benchmark assessment, propanal was the only contaminant with HQ > 1, while benchmark choice altered the ordering of contaminants below the exceedance threshold. When measured concentrations were translated into DALY-based harm, PM 2.5, formaldehyde, and derived PM 10–2.5 were identified as prospective contaminants of concern within the quantified set and together accounted for 99.3% of mean total harm among 15 contaminants with available harm inputs. Benchmark comparison, regulated harm, and DALY-based harm provided complementary interpretations of the monitored mixture. HQ quantified proximity to selected health-based benchmarks, RH the model-based harm implied at those benchmark concentrations, and DALY-based harm the model-based impact at the measured concentrations. Their joint use links benchmark screening with health-based prioritisation of site-specific office measurements.

Scientific ReportsVol. 16(1)
Eurac Research (IT)
Provincia autonoma di Bolzano - Alto Adige
Good health and well-being
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon