Generalized Gait Inputs Bias Predicted Meniscal Mechanics in Subject‐Specific Knee Joint Finite Element Models

Subject-specific gait inputs are often unavailable for knee finite element studies, where literature-based cohort-averaged, i.e., generalized, gait inputs are commonly used instead. However, the extent to which this choice affects predicted meniscal mechanics is unclear. We compared the effects of subject-specific and generalized gait inputs on meniscal mechanics using a coupled musculoskeletal-finite element framework with MRI-based knee models from three female participants. Subject-specific gait inputs were derived from motion capture and musculoskeletal modeling, whereas generalized gait inputs were taken from the literature. Both input types were applied to the same participant-specific finite element models, with unchanged geometry and material properties, to estimate bias in medial and lateral meniscal stresses, logarithmic strains, and fluid pressures during the walking stance. Compared with the subject-specific inputs, the generalized gait inputs increased predicted medial meniscus internal stresses and strains, as well as cartilage-meniscus contact surface maximum principal stress by ~50%-250% during the loading response, whereas corresponding lateral meniscus responses were reduced by ~50%. These findings indicate that generalized gait inputs can introduce compartment-specific bias in tissue-level meniscal mechanical predictions, even when subject-specific knee geometry and same material properties are used. Subject-specific gait inputs may therefore be an important feature for assessing tissue failure risk, degeneration progression, or treatment and rehabilitation effects.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2026-11-25
DOI
https://doi.org/10.1002/jor.70324
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Generalized Gait Inputs Bias Predicted Meniscal Mechanics in Subject‐Specific Knee Joint Finite Element Models

Lauri Stenroth, Marius Henriksen, Rami Kristian Korhonen, Tine Alkjær et al.
1 links
Journal of Orthopaedic Research®
Knee injuries and reconstruction techniques
article

Generalized Gait Inputs Bias Predicted Meniscal Mechanics in Subject‐Specific Knee Joint Finite Element Models

Lauri Stenroth, Marius Henriksen, Rami Kristian Korhonen, Tine Alkjær, Sana Jahangir, Alexander Paz, Will Bosch, Mika E. Mononen, Amir Esrafilian, Hanna Isaksson, Petri Tanska
article en

Abstract

Subject-specific gait inputs are often unavailable for knee finite element studies, where literature-based cohort-averaged, i.e., generalized, gait inputs are commonly used instead. However, the extent to which this choice affects predicted meniscal mechanics is unclear. We compared the effects of subject-specific and generalized gait inputs on meniscal mechanics using a coupled musculoskeletal-finite element framework with MRI-based knee models from three female participants. Subject-specific gait inputs were derived from motion capture and musculoskeletal modeling, whereas generalized gait inputs were taken from the literature. Both input types were applied to the same participant-specific finite element models, with unchanged geometry and material properties, to estimate bias in medial and lateral meniscal stresses, logarithmic strains, and fluid pressures during the walking stance. Compared with the subject-specific inputs, the generalized gait inputs increased predicted medial meniscus internal stresses and strains, as well as cartilage-meniscus contact surface maximum principal stress by ~50%-250% during the loading response, whereas corresponding lateral meniscus responses were reduced by ~50%. These findings indicate that generalized gait inputs can introduce compartment-specific bias in tissue-level meniscal mechanical predictions, even when subject-specific knee geometry and same material properties are used. Subject-specific gait inputs may therefore be an important feature for assessing tissue failure risk, degeneration progression, or treatment and rehabilitation effects.

Journal of Orthopaedic Research®Vol. 44(12)
Griffith University (AU), University of Copenhagen (DK), University of Eastern Finland (FI), Lund University (SE), Bispebjerg Hospital (DK), Copenhagen University Hospital (DK), Kuopio University Hospital (FI), Emergency Services College (FI)
Good health and well-being
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon