Multi-objective optimal configuration of flexible interconnected power grid topology for new power systems in heavy load areas

New power systems in heavy-load areas are confronted with threefold pressures, namely insufficient power supply reliability, limited renewable energy accommodation and degraded operational safety. To address the above challenges, a multi-objective optimal configuration method for flexible interconnected power grid topology oriented to heavy-load areas is proposed. Taking the energy storage-based soft open point (E-SOP) as the core regulation and control carrier, the proposed method sets economic indicators as boundary constraints, and takes power balance, node voltage and other indicators as operational constraints. A multi-objective optimal configuration model of flexible interconnected power grid topology is established with three optimization objectives: reliability (minimum load loss after faults), environmental performance (minimum curtailed renewable energy power), and safety (minimum voltage deviation and minimum load rate variance), so as to realize the optimal configuration of new power systems in heavy-load areas. A modified IEEE 33-node test system is adopted to construct a heavy-load area case for verification. The simulation results demonstrate that after optimal configuration via the proposed method, the system can complete fault power transfer within 0.05 s; the power loss is reduced by 88.6%, the comprehensive photovoltaic curtailment rate drops from 22.6% to 4.7%, the minimum node voltage rises from 0.921 p.u. to 0.956 p.u., and the load rate variance is cut down by 88.3%. The results of this study provide a quantitative reference for the planning and retrofit of distribution networks in heavy-load areas with high renewable penetration, although the conclusions are obtained under the specific assumptions of the modified IEEE 33-node case.

Authors

Institutions

Publication Details

Journal
Archives of Electrical Engineering
Published
2026-11-25
DOI
https://doi.org/10.24425/aee.2026.17590
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Multi-objective optimal configuration of flexible interconnected power grid topology for new power systems in heavy load areas

Yuqun Gao, Zexin Liu, Liujun Hu, Chen Yahao et al.
3 links
Archives of Electrical Engineering
Optimal Power Flow Distribution
article

Multi-objective optimal configuration of flexible interconnected power grid topology for new power systems in heavy load areas

Yuqun Gao, Zexin Liu, Liujun Hu, Chen Yahao, Hong Dong
article en

Abstract

New power systems in heavy-load areas are confronted with threefold pressures, namely insufficient power supply reliability, limited renewable energy accommodation and degraded operational safety. To address the above challenges, a multi-objective optimal configuration method for flexible interconnected power grid topology oriented to heavy-load areas is proposed. Taking the energy storage-based soft open point (E-SOP) as the core regulation and control carrier, the proposed method sets economic indicators as boundary constraints, and takes power balance, node voltage and other indicators as operational constraints. A multi-objective optimal configuration model of flexible interconnected power grid topology is established with three optimization objectives: reliability (minimum load loss after faults), environmental performance (minimum curtailed renewable energy power), and safety (minimum voltage deviation and minimum load rate variance), so as to realize the optimal configuration of new power systems in heavy-load areas. A modified IEEE 33-node test system is adopted to construct a heavy-load area case for verification. The simulation results demonstrate that after optimal configuration via the proposed method, the system can complete fault power transfer within 0.05 s; the power loss is reduced by 88.6%, the comprehensive photovoltaic curtailment rate drops from 22.6% to 4.7%, the minimum node voltage rises from 0.921 p.u. to 0.956 p.u., and the load rate variance is cut down by 88.3%. The results of this study provide a quantitative reference for the planning and retrofit of distribution networks in heavy-load areas with high renewable penetration, although the conclusions are obtained under the specific assumptions of the modified IEEE 33-node case.

Archives of Electrical Engineering
Guangzhou Education Bureau (CN), Guangdong Power Grid Company (China) (CN), China Energy Engineering Group Guangdong Electric Power Design Institute Co., Ltd. (China) (CN), China Southern Power Grid (China) (CN), Power Grid Corporation (India) (IN)
Affordable and clean energy, Industry, innovation and infrastructure
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon