Antimicrobial and antibiofilm surface modification of clear aligners: a systematic scoping review

This scoping review aimed to systematically identify, map, and synthesize the available evidence on antimicrobial surface modifications of clear aligners. Specifically, it sought to characterize the types of coating strategies investigated, evaluate their effects on microbial adhesion, colonization, and biofilm formation, and summarize the reported evidence regarding their stability, biocompatibility, mechanical and optical compatibility, and potential clinical applicability in clear aligner therapy. This scoping review was conducted in accordance with the PRISMA-ScR guidelines. A comprehensive literature search was performed in PubMed, Scopus, Web of Science, and Google Scholar from database inception to 30 August 2026, to identify studies evaluating antimicrobial and antibiofilm surface modifications of clear aligner materials. Two reviewers independently conducted the study selection. Data regarding coating composition, application techniques, antimicrobial and antibiofilm efficacy, coating stability, biocompatibility, and compatibility with the mechanical and optical properties of clear aligners were systematically extracted, charted, and descriptively synthesized. The search identified 413 records, of which 25 studies met the eligibility criteria. The investigated surface modifications comprised metal-based, polymeric, fluoride-releasing, biomimetic, and peptide-based coatings, most of which were applied to polyethylene terephthalate glycol substrates. Overall, these modifications demonstrated promising antimicrobial and/or antibiofilm effects, particularly against Streptococcus mutans. However, substantial heterogeneity in coating materials, application techniques, experimental models, evaluation methods, and outcome measures limited meaningful comparisons across studies. Although optical and mechanical properties were generally preserved in many studies, the findings were inconsistent, incompletely reported, and insufficient to establish long-term compatibility. Antimicrobial and antibiofilm surface modifications show considerable promise for reducing microbial adhesion, colonization, and biofilm formation on clear aligners, particularly against Streptococcus mutans. Nevertheless, the substantial heterogeneity among coating materials, application methods, testing protocols, and outcome measures, together with limited evidence on long-term stability, biocompatibility, mechanical and optical compatibility, and clinical performance, precludes definitive conclusions regarding their clinical effectiveness. Future research should prioritize standardized testing protocols, clinically relevant in vitro and in vivo models, long-term assessments, and well-designed clinical studies to establish the safety, durability, and clinical applicability of these surface modifications.

Authors

Institutions

Publication Details

Journal
The Saudi Dental Journal
Published
2026-11-25
DOI
https://doi.org/10.1007/s44445-026-00273-6
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Antimicrobial and antibiofilm surface modification of clear aligners: a systematic scoping review

Nima Ahmadi, Yasaman Sherafatmand, Hossein Ebrahimi
The Saudi Dental Journal
Dental materials and restorations
article

Antimicrobial and antibiofilm surface modification of clear aligners: a systematic scoping review

Nima Ahmadi, Yasaman Sherafatmand, Hossein Ebrahimi
article en

Abstract

This scoping review aimed to systematically identify, map, and synthesize the available evidence on antimicrobial surface modifications of clear aligners. Specifically, it sought to characterize the types of coating strategies investigated, evaluate their effects on microbial adhesion, colonization, and biofilm formation, and summarize the reported evidence regarding their stability, biocompatibility, mechanical and optical compatibility, and potential clinical applicability in clear aligner therapy. This scoping review was conducted in accordance with the PRISMA-ScR guidelines. A comprehensive literature search was performed in PubMed, Scopus, Web of Science, and Google Scholar from database inception to 30 August 2026, to identify studies evaluating antimicrobial and antibiofilm surface modifications of clear aligner materials. Two reviewers independently conducted the study selection. Data regarding coating composition, application techniques, antimicrobial and antibiofilm efficacy, coating stability, biocompatibility, and compatibility with the mechanical and optical properties of clear aligners were systematically extracted, charted, and descriptively synthesized. The search identified 413 records, of which 25 studies met the eligibility criteria. The investigated surface modifications comprised metal-based, polymeric, fluoride-releasing, biomimetic, and peptide-based coatings, most of which were applied to polyethylene terephthalate glycol substrates. Overall, these modifications demonstrated promising antimicrobial and/or antibiofilm effects, particularly against Streptococcus mutans. However, substantial heterogeneity in coating materials, application techniques, experimental models, evaluation methods, and outcome measures limited meaningful comparisons across studies. Although optical and mechanical properties were generally preserved in many studies, the findings were inconsistent, incompletely reported, and insufficient to establish long-term compatibility. Antimicrobial and antibiofilm surface modifications show considerable promise for reducing microbial adhesion, colonization, and biofilm formation on clear aligners, particularly against Streptococcus mutans. Nevertheless, the substantial heterogeneity among coating materials, application methods, testing protocols, and outcome measures, together with limited evidence on long-term stability, biocompatibility, mechanical and optical compatibility, and clinical performance, precludes definitive conclusions regarding their clinical effectiveness. Future research should prioritize standardized testing protocols, clinically relevant in vitro and in vivo models, long-term assessments, and well-designed clinical studies to establish the safety, durability, and clinical applicability of these surface modifications.

The Saudi Dental JournalVol. 38(12)
Shahed University (IR), Tehran University of Medical Sciences (IR)
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon