Trigeneration for Italian University Campuses: A Thematic Review

University campuses are major energy consumers, necessitating innovative strategies to reduce grid load while protecting the environment. In Italy, climatic conditions vary substantially across the north, central, and southern regions. This thematic review assesses which claims about trigeneration (combined cooling, heating, and power) at Italian university campuses are supported by published institutional, climatic, and plant-level evidence, and which remain hypothetical. The evidence is analysed in three interconnected stages: (i) 2024 institutional electricity data and enrolment for five universities, compared using explicit accounting boundaries and harmonised to a lower-bound basis; (ii) heating and cooling degree days for their respective cities in 2023 and 2024, calculated from hourly temperature data and used solely as indicators of outdoor temperature exposure; and (iii) documented cogeneration and trigeneration installations at eight university sites, including the characteristics of eight prime-mover and system types. Reported electricity consumption in 2024 ranges from 25 to 47 GWh (average power 2.9 to 5.4 MW) on non-comparable boundaries; the four campuses with total or lower-bound figures fall between 36.6 and 47.2 GWh (4.2 to 5.4 MW). All five cities are heating-dominated; cooling degree days account for about 30% of total degree days in Rome and Naples, compared with 10% to 17% in Milan, Turin, and Padua. On-site generation accounts for 27 to 35 per cent of campus power where data are available. The most thoroughly documented options are reciprocating engines and microturbines, while the remaining technologies are primarily experimental. Because cost, hourly load, or emission statistics are unavailable, the technology assessment is a conditional, qualitative screening rather than an optimisation, and conclusions about the suitability of individual campuses are considered hypotheses.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-24
DOI
https://doi.org/10.3390/en19235709
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Trigeneration for Italian University Campuses: A Thematic Review

Fabio Cardona, Vamsi Sagiraju
Energies
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Trigeneration for Italian University Campuses: A Thematic Review

Fabio Cardona, Vamsi Sagiraju
article en

Abstract

University campuses are major energy consumers, necessitating innovative strategies to reduce grid load while protecting the environment. In Italy, climatic conditions vary substantially across the north, central, and southern regions. This thematic review assesses which claims about trigeneration (combined cooling, heating, and power) at Italian university campuses are supported by published institutional, climatic, and plant-level evidence, and which remain hypothetical. The evidence is analysed in three interconnected stages: (i) 2024 institutional electricity data and enrolment for five universities, compared using explicit accounting boundaries and harmonised to a lower-bound basis; (ii) heating and cooling degree days for their respective cities in 2023 and 2024, calculated from hourly temperature data and used solely as indicators of outdoor temperature exposure; and (iii) documented cogeneration and trigeneration installations at eight university sites, including the characteristics of eight prime-mover and system types. Reported electricity consumption in 2024 ranges from 25 to 47 GWh (average power 2.9 to 5.4 MW) on non-comparable boundaries; the four campuses with total or lower-bound figures fall between 36.6 and 47.2 GWh (4.2 to 5.4 MW). All five cities are heating-dominated; cooling degree days account for about 30% of total degree days in Rome and Naples, compared with 10% to 17% in Milan, Turin, and Padua. On-site generation accounts for 27 to 35 per cent of campus power where data are available. The most thoroughly documented options are reciprocating engines and microturbines, while the remaining technologies are primarily experimental. Because cost, hourly load, or emission statistics are unavailable, the technology assessment is a conditional, qualitative screening rather than an optimisation, and conclusions about the suitability of individual campuses are considered hypotheses.

EnergiesVol. 19(23)
University of Palermo (IT)
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon