MXene-Based Electrochemical Detection of Alzheimer’s Disease-Associated Biomarker

Abstract c-MXene-based nanocomposites have diverse applications in electrochemical energy storage, catalysis, sensors, and biomedical diagnostics owing to their excellent electrical conductivity and large-surface area. Here, we report the fabrication of an MXene-based reusable, label-free, and non-invasive electrochemical biosensor for the detection of miRNA-128, a biomarker associated with Alzheimer’s disease (AD). The biosensor was constructed by immobilizing Am-cDNA on a c-MXene-modified chitosan (CS) layer deposited onto the FTO electrode. Following fabrication, the modified electrode (Am-cDNA/c-MXene/CS/FTO) was characterized using FTIR, FESEM, EIS, and CV, confirming its successful fabrication and ability to detect miRNA-128. The biosensor exhibited high target affinity, with a linear range of 1.0 × 10−2 fM to 1.0 × 101 nM, LOD of 0.27 fM, and a sensitivity of 18.34 Ω/fM−1 cm−2. The electrochemical biosensor successfully distinguished miRNA-128 from the sample having total mismatch and one base mismatch sequences, demonstrating its specificity. Furthermore, the proposed biosensor demonstrated its ability to distinguish AD patients from healthy individuals. Compared with conventional RT-PCR methods, this biosensor exhibited an AUC of 0.95 and 0.94, with a sensitivity of 90.6% and 84.1%, respectively. These finding demonstrate a non-invasive approach that can also accelerate therapeutic screening and support the development of effective interventions for AD. However, the improvement in sensitivity and repeatability of the developed biosensor can be enhanced by exploring more efficient biorecognition elements and enabling the simultaneous detection of multiple miRNAs for improved AD diagnosis.

Authors

Institutions

Publication Details

Journal
ACS Applied Nano Materials
Published
2026-11-25
DOI
https://doi.org/10.1021/acsanm.6c04342
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

MXene-Based Electrochemical Detection of Alzheimer’s Disease-Associated Biomarker

Rajat Sandhir, Karthik Vinay Mahesh, Nirmal Prabhakar, Savita Chaudhary et al.
1 links
ACS Applied Nano Materials
Advanced biosensing and bioanalysis techniques
article

MXene-Based Electrochemical Detection of Alzheimer’s Disease-Associated Biomarker

Rajat Sandhir, Karthik Vinay Mahesh, Nirmal Prabhakar, Savita Chaudhary, Sonia Rani, Ayushi Atri
article en

Abstract

Abstract c-MXene-based nanocomposites have diverse applications in electrochemical energy storage, catalysis, sensors, and biomedical diagnostics owing to their excellent electrical conductivity and large-surface area. Here, we report the fabrication of an MXene-based reusable, label-free, and non-invasive electrochemical biosensor for the detection of miRNA-128, a biomarker associated with Alzheimer’s disease (AD). The biosensor was constructed by immobilizing Am-cDNA on a c-MXene-modified chitosan (CS) layer deposited onto the FTO electrode. Following fabrication, the modified electrode (Am-cDNA/c-MXene/CS/FTO) was characterized using FTIR, FESEM, EIS, and CV, confirming its successful fabrication and ability to detect miRNA-128. The biosensor exhibited high target affinity, with a linear range of 1.0 × 10−2 fM to 1.0 × 101 nM, LOD of 0.27 fM, and a sensitivity of 18.34 Ω/fM−1 cm−2. The electrochemical biosensor successfully distinguished miRNA-128 from the sample having total mismatch and one base mismatch sequences, demonstrating its specificity. Furthermore, the proposed biosensor demonstrated its ability to distinguish AD patients from healthy individuals. Compared with conventional RT-PCR methods, this biosensor exhibited an AUC of 0.95 and 0.94, with a sensitivity of 90.6% and 84.1%, respectively. These finding demonstrate a non-invasive approach that can also accelerate therapeutic screening and support the development of effective interventions for AD. However, the improvement in sensitivity and repeatability of the developed biosensor can be enhanced by exploring more efficient biorecognition elements and enabling the simultaneous detection of multiple miRNAs for improved AD diagnosis.

ACS Applied Nano Materials
Post Graduate Institute of Medical Education and Research (IN), Panjab University (IN)
Department of Biotechnology, Ministry of Science and Technology, India, University Grants Commission
Good health and well-being
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon