CFD-guided design and optimization of an off-grid solar-powered refrigerator for fruit and vegetable storage in rural Sub-Saharan Africa
METHODS: A 50 L cabinet for 10 kg of mixed produce was designed for stand-alone rural operation from a 200 Wp photovoltaic (PV) module, an MPPT controller and a 0.8 kWh LiFePO4 battery. The hardware uses an R134a DC vapor-compression circuit, 40 mm polyurethane insulation, a 1.5 mm galvanized outer shell, a 1.0 mm aluminium liner, a rear microchannel evaporator, a perforated supply plenum, an electronically commutated fan and 1 kg of 5 °C phase-change material (PCM). Thermal performance was obtained from a fully specified three-dimensional ANSYS Fluent model that solves the transient Reynolds-averaged Navier-Stokes equations with Boussinesq buoyancy and the SST k-ω closure, Darcy-Forchheimer resistance in the produce stacks, conjugate energy equations for air, walls and produce, and an enthalpy-porosity PCM formulation, loosely coupled to an R134a compressor map and a PV/battery balance. Five discrete design cases (C0-C4) were ranked by a constrained multi-objective criterion on pull-down time, air-temperature spread ΔT, daily electrical energy E_d, cycle COP, useful-zone velocity and passive holdover, subject to explicit bounds on setpoint, energy, cost, fan speed, PV size and local manufacturability. DATA: Relative to the unmanaged baseline cabinet, the selected configuration C4 reduced the cyclic air-temperature spread from 6.4 °C to 2.0 °C, shortened 10 kg pull-down from 3.6 h to 2.5 h, and lowered predicted daily energy at 35 °C from 0.68 to 0.51 kWh day-1 (COP = 1.62). At 43 °C ambient the same cabinet remained at 0.74 kWh day-1. The PCM pack provided 4.0 h of passive holdover after a power cut. A conventional grid-powered 50 L compact refrigerator serving the same 10 kg load with twelve 30 s door openings at 35 °C is estimated, from published compact-appliance ratings derated to tropical duty, to consume 0.90-1.10 kWh day-1. C4 therefore uses 43-54% less electricity than that conventional baseline, or 143-215 kWh year-1, without drawing any grid energy. Refrigerator hardware is costed at approximately USD 294 and the complete off-grid kit at USD 569. Mesh M3 (0.98 × 106 cells) has a fine-grid GCI of 0.8% on mean air temperature; the domain heat-balance error is 0.7%. CONCLUSION: The first-order design lever is cabinet airflow management, not compressor oversizing: the plenum accounts for most of the uniformity and pull-down gain, while the PCM is a resilience lever that trades 0.2 h of pull-down for 4.0 h of holdover. The resulting appliance is locally fabricable, but R134a charging and recovery must be performed only by a trained refrigeration technician. Commodity-specific setpoints and prototype validation against the defined outputs remain prerequisites for field deployment.
Authors
- Vicent Marwa (ORCID: https://orcid.org/0009-0008-2679-1863)
Institutions
- Mbeya University of Science and Technology (TZ)
Publication Details
- Journal
- PLoS ONE
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1371/journal.pone.0363334
- Primary Topic
- Refrigeration and Air Conditioning Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00