Torsional and cyclic fatigue resistance of three rotary systems: An in vitro fractographic study

Background: The fracture of Nickel-Titanium (NiTi) rotary instruments during root canal preparation is primarily attributed to torsional stress and cyclic fatigue, making the evaluation of these properties clinically significant. Aims: To evaluate torsional, cyclic fatigue resistance (CFR) and fractographic analysis of 4% Endo Direct Proshape Conserve, Hyflex controlled memory (HCM) and ProTaper Ultimate (PTU) Shaper files. Settings and Design: This is an in vitro study. Materials and Methods: Twenty new NiTi rotary files (Size 20, 4% taper, 25 mm) are used per group: Group 1 (EndoDirect ProShape Conserve), Group 2 (HCM), and Group 3 (PTU Shaper). Each group (n = 20) is divided into two subgroups (n = 10): Subgroup A for torsional resistance (TR) testing (1A, 2A, 3A) and Subgroup B for CFR testing (1B, 2B, 3B). For TR, the apical 3 mm is rotated clockwise in a torsion tester until fracture, recording breaking torque, rotations to fracture, and fracture time. For CFR, files are rotated within a customized stainless-steel canal simulating 60° curvature with a 5 mm radius until fracture; time to fracture is recorded and converted to number of cycles to fracture (NCF). Statistical Analysis: Data is analyzed using One-way analysis of variance and Bonferroni post hoc tests (P < 0.05). Results: Sub group 2A showed highest mean breaking torque, indicating superior torsional resistance. Sub group 3B demonstrated highest CFR, followed by Sub group 1B. Significant intergroup differences are observed for both TR and CFR. Conclusions: HCM files exhibited superior torsional resistance, whereas PTU Shaper files demonstrated highest CFR.

Authors

Publication Details

Journal
Journal of Conservative Dentistry and Endodontics
Published
2026-11-25
DOI
https://doi.org/10.4103/jcde.jcde_884_26
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Torsional and cyclic fatigue resistance of three rotary systems: An in vitro fractographic study

Sayesh Vemuri, Roopadevi Garlapati, Nagesh Bolla, Bathula Vimala Chaitanya et al.
3 links
Journal of Conservative Dentistry and Endodontics
Endodontics and Root Canal Treatments
article

Torsional and cyclic fatigue resistance of three rotary systems: An in vitro fractographic study

Sayesh Vemuri, Roopadevi Garlapati, Nagesh Bolla, Bathula Vimala Chaitanya, Divya Sri Boggarapu, Sai Manogna Mandem
article en

Abstract

Background: The fracture of Nickel-Titanium (NiTi) rotary instruments during root canal preparation is primarily attributed to torsional stress and cyclic fatigue, making the evaluation of these properties clinically significant. Aims: To evaluate torsional, cyclic fatigue resistance (CFR) and fractographic analysis of 4% Endo Direct Proshape Conserve, Hyflex controlled memory (HCM) and ProTaper Ultimate (PTU) Shaper files. Settings and Design: This is an in vitro study. Materials and Methods: Twenty new NiTi rotary files (Size 20, 4% taper, 25 mm) are used per group: Group 1 (EndoDirect ProShape Conserve), Group 2 (HCM), and Group 3 (PTU Shaper). Each group (n = 20) is divided into two subgroups (n = 10): Subgroup A for torsional resistance (TR) testing (1A, 2A, 3A) and Subgroup B for CFR testing (1B, 2B, 3B). For TR, the apical 3 mm is rotated clockwise in a torsion tester until fracture, recording breaking torque, rotations to fracture, and fracture time. For CFR, files are rotated within a customized stainless-steel canal simulating 60° curvature with a 5 mm radius until fracture; time to fracture is recorded and converted to number of cycles to fracture (NCF). Statistical Analysis: Data is analyzed using One-way analysis of variance and Bonferroni post hoc tests (P < 0.05). Results: Sub group 2A showed highest mean breaking torque, indicating superior torsional resistance. Sub group 3B demonstrated highest CFR, followed by Sub group 1B. Significant intergroup differences are observed for both TR and CFR. Conclusions: HCM files exhibited superior torsional resistance, whereas PTU Shaper files demonstrated highest CFR.

Journal of Conservative Dentistry and EndodonticsVol. 29(12)
Good health and well-being
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon