Dynamic Macro-Microvascular Coupling During Cerebrovascular Reactivity Revealed by Simultaneous TCD and DCS

Background Transcranial Doppler (TCD) measures flow velocity in large intracranial arteries but provides limited information on microvascular perfusion.Diffuse correlation spectroscopy (DCS) enables continuous, noninvasive assessment of cortical microvascular blood flow. We compared macrovascular and microvascular responses during cerebrovascular reactivity testing. Methods Forty-four healthy adults (28 men; mean age, 27.0±3.8 years) underwent simultaneous bilateral TCD and DCS during a breath-holding task (1-minute baseline, 30-second breath hold, and 1-minute recovery). Middle cerebral artery flow velocity and cortical microvascular blood flow index were normalized to baseline (rCBFv and rCBFi, respectively). Temporal responses were compared using Pearson correlation and Bland-Altman analyses. Response amplitude, rise time, and recovery time were also assessed. Results TCD and DCS showed concordant response trajectories during breath holding and recovery. Correlations between normalized temporal responses were strong in both hemispheres (left,r=0.988±0.009;right, r=0.990±0.008; both P<0.001). Bland-Altman analysis showed minimal systematic bias and no proportional bias. No significant interhemispheric differences were observed in response amplitude, rise time, or recovery time. DCS-derived rCBFi showed greater response amplitudes and variability than TCD-derived rCBFv (left, 1.80±0.34 vs 1.63±0.15; right, 1.72±0.27 vs 1.63±0.14). Parameter-level analyses showed strong correlations and minimal bias for response amplitude, rise time, and recovery time. Conclusions TCD and DCS demonstrated strong temporal coupling during cerebrovascular reactivity testing, while DCS detected larger response amplitudes than TCD. These findings suggest that macrovascular velocity and cortical microvascular perfusion provide complementary information about cerebrovascular responses.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-11-24
DOI
https://doi.org/10.64898/2026.11.23.26368800
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Dynamic Macro-Microvascular Coupling During Cerebrovascular Reactivity Revealed by Simultaneous TCD and DCS

Xiangyu Cao, Zhe Li, Hui Su, Yiwen Wang et al.
medRxiv
Optical Imaging and Spectroscopy Techniques
preprint

Dynamic Macro-Microvascular Coupling During Cerebrovascular Reactivity Revealed by Simultaneous TCD and DCS

Xiangyu Cao, Zhe Li, Hui Su, Yiwen Wang, Zhe Ji, Yi-Qin Han
preprint en

Abstract

Background Transcranial Doppler (TCD) measures flow velocity in large intracranial arteries but provides limited information on microvascular perfusion.Diffuse correlation spectroscopy (DCS) enables continuous, noninvasive assessment of cortical microvascular blood flow. We compared macrovascular and microvascular responses during cerebrovascular reactivity testing. Methods Forty-four healthy adults (28 men; mean age, 27.0±3.8 years) underwent simultaneous bilateral TCD and DCS during a breath-holding task (1-minute baseline, 30-second breath hold, and 1-minute recovery). Middle cerebral artery flow velocity and cortical microvascular blood flow index were normalized to baseline (rCBFv and rCBFi, respectively). Temporal responses were compared using Pearson correlation and Bland-Altman analyses. Response amplitude, rise time, and recovery time were also assessed. Results TCD and DCS showed concordant response trajectories during breath holding and recovery. Correlations between normalized temporal responses were strong in both hemispheres (left,r=0.988±0.009;right, r=0.990±0.008; both P<0.001). Bland-Altman analysis showed minimal systematic bias and no proportional bias. No significant interhemispheric differences were observed in response amplitude, rise time, or recovery time. DCS-derived rCBFi showed greater response amplitudes and variability than TCD-derived rCBFv (left, 1.80±0.34 vs 1.63±0.15; right, 1.72±0.27 vs 1.63±0.14). Parameter-level analyses showed strong correlations and minimal bias for response amplitude, rise time, and recovery time. Conclusions TCD and DCS demonstrated strong temporal coupling during cerebrovascular reactivity testing, while DCS detected larger response amplitudes than TCD. These findings suggest that macrovascular velocity and cortical microvascular perfusion provide complementary information about cerebrovascular responses.

medRxiv
Chinese PLA General Hospital (CN), Beijing University of Technology (CN), Chinese People's Liberation Army (CN)
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon