BiCE-MTXNet: Explainable Bidirectional Multi-Task Learning with Exact Branch Attribution for Dermoscopic Segmentation and Diagnosis

Joint dermoscopic analysis requires accurate lesion delineation, multi-class diagnostic discrimination, and transparent evidence attribution. We present the Bidirectional Concept-Equilibrium Multi-Task Network (BiCE-MTXNet) for joint full-field segmentation and seven-class dermoscopic diagnosis. Separate DINOv2-based feature pyramids process aspect-preserving 448×448 images, while a luminance occlusion gate weights valid support prior to quadratic Bernstein pooling across core, border, and context regions, combining 16 optical and morphological descriptors with 18 descriptor-regularized regional proxies. Diagnostic-conditioned feature-wise linear modulation and an anisotropic screened-Poisson equilibrium layer couple preliminary diagnostic signals to boundary estimation via residual-corrected mixed-precision Jacobi-preconditioned conjugate gradients with implicit differentiation, updating regional support for a second-pass five-branch additive readout that yields exact conditional branch Shapley values in one forward pass. Seven benchmark arms and seven retrained Stage-2 reduced architectures were evaluated across 4210 images spanning HAM10000 development and test splits, PH2, and ISIC 2016. Under matched four-view inference, BiCE-MTXNet achieved 95.41% development and 95.18% test Dice (retaining standalone segmentation overlap while improving test two-pixel boundary F1 by +9.68 and +2.51 percentage points over shared-encoder and one-way multi-task baselines), alongside 97.91% test macro-AUROC, 87.92% macro-average precision, and 81.08% macro-F1 (+7.74 percentage points over standalone classification). External Dice reached 92.95% on PH2 and 92.16% on ISIC 2016, with 87.50%PH2 melanoma sensitivity and 81.25% specificity and lower external deletion area under the curve (0.2282 versus 0.3002 for mask-only attribution, pHolm=0.0072). Controlled Stage-2 ablations confirm that decoupled spatial–semantic trunks and regional Bernstein pooling drive the primary contour and diagnostic gains, while the proxy, modulation, and equilibrium modules preserve standalone overlap and provide differentiable coupling and readout inspectability.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-11-25
DOI
https://doi.org/10.3390/bioengineering13121438
Primary Topic
Cutaneous Melanoma Detection and Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

BiCE-MTXNet: Explainable Bidirectional Multi-Task Learning with Exact Branch Attribution for Dermoscopic Segmentation and Diagnosis

Khalid Alhussaini, Nabil Ali Alrajeh, Zaied Alhaj
2 links
Bioengineering
Cutaneous Melanoma Detection and Management
article

BiCE-MTXNet: Explainable Bidirectional Multi-Task Learning with Exact Branch Attribution for Dermoscopic Segmentation and Diagnosis

Khalid Alhussaini, Nabil Ali Alrajeh, Zaied Alhaj
article en

Abstract

Joint dermoscopic analysis requires accurate lesion delineation, multi-class diagnostic discrimination, and transparent evidence attribution. We present the Bidirectional Concept-Equilibrium Multi-Task Network (BiCE-MTXNet) for joint full-field segmentation and seven-class dermoscopic diagnosis. Separate DINOv2-based feature pyramids process aspect-preserving 448×448 images, while a luminance occlusion gate weights valid support prior to quadratic Bernstein pooling across core, border, and context regions, combining 16 optical and morphological descriptors with 18 descriptor-regularized regional proxies. Diagnostic-conditioned feature-wise linear modulation and an anisotropic screened-Poisson equilibrium layer couple preliminary diagnostic signals to boundary estimation via residual-corrected mixed-precision Jacobi-preconditioned conjugate gradients with implicit differentiation, updating regional support for a second-pass five-branch additive readout that yields exact conditional branch Shapley values in one forward pass. Seven benchmark arms and seven retrained Stage-2 reduced architectures were evaluated across 4210 images spanning HAM10000 development and test splits, PH2, and ISIC 2016. Under matched four-view inference, BiCE-MTXNet achieved 95.41% development and 95.18% test Dice (retaining standalone segmentation overlap while improving test two-pixel boundary F1 by +9.68 and +2.51 percentage points over shared-encoder and one-way multi-task baselines), alongside 97.91% test macro-AUROC, 87.92% macro-average precision, and 81.08% macro-F1 (+7.74 percentage points over standalone classification). External Dice reached 92.95% on PH2 and 92.16% on ISIC 2016, with 87.50%PH2 melanoma sensitivity and 81.25% specificity and lower external deletion area under the curve (0.2282 versus 0.3002 for mask-only attribution, pHolm=0.0072). Controlled Stage-2 ablations confirm that decoupled spatial–semantic trunks and regional Bernstein pooling drive the primary contour and diagnostic gains, while the proxy, modulation, and equilibrium modules preserve standalone overlap and provide differentiable coupling and readout inspectability.

BioengineeringVol. 13(12)
King Saud University (SA)
King Saud University
Good health and well-being
Cutaneous Melanoma Detection and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon