Hair Cosmetics and Thermal Styling: Formaldehyde Release and Human Safety Analysis
Background The widespread use of hair‐straightening and smoothing products has increased concern regarding the effects of potential formaldehyde exposure during cosmetic procedures on users and hairdressers' health. Aims We investigated the release of formaldehyde from a hair‐straightening mask during application and thermal styling, exploring potential sources, health risks, and safety measures. Participants/Methods Cutaneous, ocular, and respiratory acceptability were evaluated at three time points: baseline, 24 h, and 21 days post‐application. Thirty‐four women (aged 23–69) with various hair types were included. The product was applied by two professional hairdressers, and participants were assessed by dermatologists, ophthalmologists, and otolaryngologists. Perception of discomfort was recorded using a study‐specific investigative questionnaire, a symptom‐oriented discomfort questionnaire, and a daily diary. To evaluate formaldehyde exposure, six air samples were collected using pumps with silica gel tubes with 2,4‐Dinitrophenylhydrazine (DNPH). Sampling included personal (breathing zone) and room air monitoring with data interpreted as short‐duration and partial‐period measurements. Formaldehyde was quantified by high‐performance liquid chromatography with ultraviolet detection at 360 nm, as specified in NIOSH Method 2016. All samples were analyzed by an ISO 17025:2017‐accredited laboratory. Results Thirty‐four participants completed the study. No clinical signs or symptoms of cutaneous, ocular, or respiratory discomfort were observed or reported. Formaldehyde concentrations, calculated as time‐weighted averages (TWA) over 480 min, ranged from 0.02 to 0.03 ppm, with the highest estimated TWA being 0.03 ppm for personal sampling and 0.02 ppm for room sampling. Under the tested conditions, these values remained low in relation to several occupational exposure limits and health‐based guideline values. Conclusions The absence of adverse events, together with low airborne formaldehyde concentrations under the tested conditions, suggests favorable short‐term tolerability of the evaluated product when used according to the recommended application procedure. These findings reinforce the importance of appropriate application practices, continued occupational hygiene monitoring, and comprehensive safety assessments to support consumer and occupational safety.
Authors
- Janaina Rosa Cortinóz
- Lucas Offenbecker Guerra
- Gabrielli Brianezi (ORCID: https://orcid.org/0000-0003-3482-0296)
- Andrezza Di Pietro Micali Canavez (ORCID: https://orcid.org/0000-0002-4983-7464)
- Desirée Cigaran Schuck (ORCID: https://orcid.org/0000-0001-9415-4913)
- Dayane Seco Carrari Budie (ORCID: https://orcid.org/0009-0006-9503-1193)
- Fabiana Parussolo Laranjeira (ORCID: https://orcid.org/0009-0000-7730-0966)
- Érika Alegrio Jarque Petali (ORCID: https://orcid.org/0009-0004-6352-3236)
- Andrea Misun Kim (ORCID: https://orcid.org/0009-0000-4793-5143)
Publication Details
- Journal
- Journal of Cosmetic Dermatology
- Published
- 2026-11-24
- DOI
- https://doi.org/10.1111/jocd.71297
- Primary Topic
- Contact Dermatitis and Allergies
- Type
- article
- Field-Weighted Citation Impact
- 0.00