Steric-Hindrance Elimination Coupled with Interfacial Enrichment for Ultrasensitive Electrochemical Biosensing

Electrochemical biosensors for biological targets are fundamentally constrained by interfacial steric hindrance, which limits target accessibility in conventional capture-at-interface architectures. Herein, we report a steric-hindrance elimination coupled with an interfacial enrichment strategy for ultrasensitive electrochemical biosensing. Instead of performing molecular recognition at the electrode surface, target recognition was accomplished homogeneously on magnetic nanoparticles, followed by magnetic separation to isolate released methylene blue-labeled DNA (MB-DNA) signaling probes from bulky biological targets. This design effectively eliminates steric constraints while transforming complex recognition events into the detection of freely diffusing electroactive probes. To maximize the electrochemical output of each released probe, a MoS2-modified electrode was engineered to establish an interfacial enrichment layer through strong ssDNA-MoS2 interactions, concentrating MB-DNA at the electrode interface, and significantly increasing the number of electroactive probes available for signal transduction. Using nucleolin as a representative biological target, the biosensor exhibited a wide linear range from 10 fg/mL to 1 μg/mL with a detection limit of 5.37 fg/mL, together with excellent selectivity, reproducibility, and stability. The platform successfully discriminated plasma samples from lung cancer patients and healthy individuals and accurately differentiated nucleolin-positive lung cancer cells from normal cells. This work establishes a general electrochemical biosensing framework in which analytical sensitivity is achieved by combining steric-hindrance elimination with interfacial enrichment, providing a versatile strategy readily adaptable to diverse biological targets through replacement of the recognition element.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2026-11-25
DOI
https://doi.org/10.1021/acssensors.6c03384
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Steric-Hindrance Elimination Coupled with Interfacial Enrichment for Ultrasensitive Electrochemical Biosensing

Yang Huang, Sheng Wang, Jialiang Guo, Shengfeng Huang et al.
4 links
ACS Sensors
Advanced biosensing and bioanalysis techniques
article

Steric-Hindrance Elimination Coupled with Interfacial Enrichment for Ultrasensitive Electrochemical Biosensing

Yang Huang, Sheng Wang, Jialiang Guo, Shengfeng Huang, Xiyu Chen, Xiaoting Zhang, Shuo Yang
article en

Abstract

Electrochemical biosensors for biological targets are fundamentally constrained by interfacial steric hindrance, which limits target accessibility in conventional capture-at-interface architectures. Herein, we report a steric-hindrance elimination coupled with an interfacial enrichment strategy for ultrasensitive electrochemical biosensing. Instead of performing molecular recognition at the electrode surface, target recognition was accomplished homogeneously on magnetic nanoparticles, followed by magnetic separation to isolate released methylene blue-labeled DNA (MB-DNA) signaling probes from bulky biological targets. This design effectively eliminates steric constraints while transforming complex recognition events into the detection of freely diffusing electroactive probes. To maximize the electrochemical output of each released probe, a MoS2-modified electrode was engineered to establish an interfacial enrichment layer through strong ssDNA-MoS2 interactions, concentrating MB-DNA at the electrode interface, and significantly increasing the number of electroactive probes available for signal transduction. Using nucleolin as a representative biological target, the biosensor exhibited a wide linear range from 10 fg/mL to 1 μg/mL with a detection limit of 5.37 fg/mL, together with excellent selectivity, reproducibility, and stability. The platform successfully discriminated plasma samples from lung cancer patients and healthy individuals and accurately differentiated nucleolin-positive lung cancer cells from normal cells. This work establishes a general electrochemical biosensing framework in which analytical sensitivity is achieved by combining steric-hindrance elimination with interfacial enrichment, providing a versatile strategy readily adaptable to diverse biological targets through replacement of the recognition element.

ACS Sensors
Foshan University (CN), Guangzhou Medical University (CN)
National Natural Science Foundation of China, Bureau of Education of Guangzhou Municipality, Basic and Applied Basic Research Foundation of Guangdong Province
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon