Balancing Directions and Averages for Cardiac Diffusion Tensor Imaging Using a Moderate Gradient Performance System

Cardiac diffusion tensor imaging (cDTI) is an inherently low signal‐to‐noise ratio technique while also having long scan times. This generally results in suboptimal image quality, especially for systems with moderate gradient performance, for fixed durations of scan time. The aim of this study was to evaluate several diffusion encoding schemes (DES) on a moderate gradient performance, 3T scanner, while fixing the number of diffusion‐weighted images to objectively determine which DES yielded superior results. Spin‐echo cDTI protocols spanning six DES were evaluated in healthy subjects (N = 10). Each DES used a combination diffusion directions (N) and signal averages (N). Mean diffusivity (MD), fractional anisotropy (FA), and the helix angle pitch (HAP), plus MD uncertainty ( MD), FA uncertainty ( FA), and the primary eigenvector uncertainty () were analyzed for statistical differences (p < 0.05). The technique for order of preference by similarity to ideal solution (TOPSIS) method was used to identify which DES yielded superior results. DES with lower N /higher N had lower FA, MD, and FA. As N increased/N decreased, FA, MD, and FA increased. Inversely, DES with lower N /higher N had a higher , while N increased/N decreased, the decreased. The HAP had a parabolic trend where both DES with lower N /higher N and DES with higher N /lower N were not as steep as DES with moderate N /moderate N. The DES with moderate N (15)/moderate N (4) yielded the most superior results. This work provides a framework for evaluating the best DES for cDTI on systems with moderate gradient performance.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-11-25
DOI
https://doi.org/10.1002/nbm.70445
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Balancing Directions and Averages for Cardiac Diffusion Tensor Imaging Using a Moderate Gradient Performance System

Matthew J. Middione, Ariel J. Hannum, Daniel B. Ennis, Tyler E. Cork
5 links
NMR in Biomedicine
Advanced Neuroimaging Techniques and Applications
article

Balancing Directions and Averages for Cardiac Diffusion Tensor Imaging Using a Moderate Gradient Performance System

Matthew J. Middione, Ariel J. Hannum, Daniel B. Ennis, Tyler E. Cork
article en

Abstract

Cardiac diffusion tensor imaging (cDTI) is an inherently low signal‐to‐noise ratio technique while also having long scan times. This generally results in suboptimal image quality, especially for systems with moderate gradient performance, for fixed durations of scan time. The aim of this study was to evaluate several diffusion encoding schemes (DES) on a moderate gradient performance, 3T scanner, while fixing the number of diffusion‐weighted images to objectively determine which DES yielded superior results. Spin‐echo cDTI protocols spanning six DES were evaluated in healthy subjects (N = 10). Each DES used a combination diffusion directions (N) and signal averages (N). Mean diffusivity (MD), fractional anisotropy (FA), and the helix angle pitch (HAP), plus MD uncertainty ( MD), FA uncertainty ( FA), and the primary eigenvector uncertainty () were analyzed for statistical differences (p < 0.05). The technique for order of preference by similarity to ideal solution (TOPSIS) method was used to identify which DES yielded superior results. DES with lower N /higher N had lower FA, MD, and FA. As N increased/N decreased, FA, MD, and FA increased. Inversely, DES with lower N /higher N had a higher , while N increased/N decreased, the decreased. The HAP had a parabolic trend where both DES with lower N /higher N and DES with higher N /lower N were not as steep as DES with moderate N /moderate N. The DES with moderate N (15)/moderate N (4) yielded the most superior results. This work provides a framework for evaluating the best DES for cDTI on systems with moderate gradient performance.

NMR in BiomedicineVol. 40(1)
VA Palo Alto Health Care System (US), Veterans Health Administration (US), Stanford Medicine (US), Stanford Cardiovascular Institute (US), Stanford University (US)
National Institutes of Health, National Heart, Lung, and Blood Institute
Good health and well-being
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon