Image quality evaluation of dual deep learning accelerated post-contrast Magnetization Prepared Rapid Gradient Echo (MPRAGE) imaging at 1.5 T and 3 T MRI
BackgroundHigh-resolution 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) imaging is widely used in routine clinical practice; however, it can have long acquisition time.PurposeTo evaluate image quality of a new deep-learning technique, Sonic DL™ 3D (SDL), combined with older version of DL (AIR™ Recon DL, ADL) for whole brain post-contrast MPRAGE versus ADL alone at both 1.5-T and 3-T scanners.Material and MethodsA total of 39 and 50 consecutive patients underwent brain MRI, including post-contrast SDL-MPRAGE (acquisition time (TA): 1 min 42 s at 1.5 T and 1 min 36 s at 3 T) and ADL-MPRAGE (TA: 2 min 21 s at 1.5 T and 2 min 15 s at 3 T) at 1.5 T and 3 T, respectively. The anonymized and randomized imaging datasets were reviewed by two neuroradiologists independently by randomized head-to-head comparison using a pre-defined 5-point scale across six categories. Interrater agreement was assessed. Non-inferiority of SDL-MPRAGE was tested using a 15% margin.ResultsInterrater agreement ranged from poor to moderate at 1.5 T (κ: -0.044 to 0.553 at 1.5 T and κ: 0.000-0.560 at 3 T). SDL-MPRAGE was non-inferior in 2/6 image quality categories at 1.5 T (GM/WM differentiation and pathological enhancement) and in 5/6 categories at 3 T (noise, GM/WM differentiation, sharpness, overall diagnostic quality, and pathological enhancement). At 3 T, SDL-MPRAGE additionally demonstrated superiority over standard MPRAGE for perceived noise category.ConclusionSDL-MPRAGE demonstrated non-inferiority in majority of the image quality categories at 3 T, potentially enabling a way for improved and more time-efficient MPRAGE acquisition.
Authors
- Chen-Hua Chiang (ORCID: https://orcid.org/0000-0001-8650-4119)
- Ivan Jambor (ORCID: https://orcid.org/0000-0001-6305-3570)
- Eugene Milshteyn (ORCID: https://orcid.org/0000-0003-0213-7003)
- Mary Thomas
- Susie Y. Huang
- Dan Rettman
Institutions
- Harvard University (US)
- University of Turku (FI)
- Massachusetts General Hospital (US)
- Ministry of Health and Welfare (TW)
- Taipei Medical University-Shuang Ho Hospital (TW)
- Taipei Medical University (TW)
- Mass General Brigham (US)
Publication Details
- Journal
- Acta Radiologica
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1177/02841851261509368
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00