Nonlinear Hemodynamic Responses to Mid-LAD Stenosis: A Computational Fluid Dynamics Study of the Whole Left Coronary Circulation

The hemodynamic effects of mid-segment left anterior descending artery (LAD) stenosis on the entire left coronary circulation remain incompletely understood. This study investigated these effects using computational fluid dynamics (CFD). Three-dimensional left coronary artery models with mid-LAD stenosis of 15%, 30%, 45%, 55%, 70%, and 80% were constructed. Velocity, trans-stenotic pressure gradient, CFD-derived fractional flow reserve (CFD-FFR), time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT) were evaluated to characterize changes in coronary hemodynamics. Mid-LAD stenosis produced nonlinear alterations in coronary hemodynamics, with a distinct transition observed at approximately 55% stenosis. At ≥ 55% stenosis, trans-stenotic pressure loss increased markedly, accompanied by reduction in LAD CFD-FFR and substantial expansion of low-TAWSS, high-OSI, and elevated-RRT regions. A modest increase in flow velocity in non-LAD branches was also observed, suggesting redistribution of coronary flow within the left coronary network. Mid-LAD stenosis induces nonlinear changes in whole-left-coronary hemodynamics, with approximately 55% representing a study-specific transition point associated with amplified pressure loss, functional impairment, and adverse shear-related flow characteristics. The divergence between anatomical stenosis severity and functional hemodynamic impairment highlights the potential limitations of morphological assessment alone and supports CFD-based hemodynamic analysis as a complementary approach for characterizing intermediate mid-LAD stenosis.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Development and Disease
Published
2026-11-25
DOI
https://doi.org/10.3390/jcdd13120623
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Nonlinear Hemodynamic Responses to Mid-LAD Stenosis: A Computational Fluid Dynamics Study of the Whole Left Coronary Circulation

Jian Liu, Meng Guo, Xiaofeng Su, Qingdong Wang et al.
2 links
Journal of Cardiovascular Development and Disease
Coronary Interventions and Diagnostics
article

Nonlinear Hemodynamic Responses to Mid-LAD Stenosis: A Computational Fluid Dynamics Study of the Whole Left Coronary Circulation

Jian Liu, Meng Guo, Xiaofeng Su, Qingdong Wang, Wenhao Pan, Xin Peng
article en

Abstract

The hemodynamic effects of mid-segment left anterior descending artery (LAD) stenosis on the entire left coronary circulation remain incompletely understood. This study investigated these effects using computational fluid dynamics (CFD). Three-dimensional left coronary artery models with mid-LAD stenosis of 15%, 30%, 45%, 55%, 70%, and 80% were constructed. Velocity, trans-stenotic pressure gradient, CFD-derived fractional flow reserve (CFD-FFR), time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT) were evaluated to characterize changes in coronary hemodynamics. Mid-LAD stenosis produced nonlinear alterations in coronary hemodynamics, with a distinct transition observed at approximately 55% stenosis. At ≥ 55% stenosis, trans-stenotic pressure loss increased markedly, accompanied by reduction in LAD CFD-FFR and substantial expansion of low-TAWSS, high-OSI, and elevated-RRT regions. A modest increase in flow velocity in non-LAD branches was also observed, suggesting redistribution of coronary flow within the left coronary network. Mid-LAD stenosis induces nonlinear changes in whole-left-coronary hemodynamics, with approximately 55% representing a study-specific transition point associated with amplified pressure loss, functional impairment, and adverse shear-related flow characteristics. The divergence between anatomical stenosis severity and functional hemodynamic impairment highlights the potential limitations of morphological assessment alone and supports CFD-based hemodynamic analysis as a complementary approach for characterizing intermediate mid-LAD stenosis.

Journal of Cardiovascular Development and DiseaseVol. 13(12)
Peking University People's Hospital (CN)
Good health and well-being
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Nonlinear Hemodynamic Responses to Mid-LAD Stenosis: A Computational Fluid Dynamics Study of the Whole Left Coronary Circulation — Jian Liu, Meng Guo, et al. · Journal of Cardiovascular Development and Disease (2026) | TGRS Research Map | TGRS