Stereoacuity Assessment in Children: Testability, Repeatability, and Inter-Test Agreement Among TNO, Frisby and YRDS3 Stereotests

Background/Objectives: To identify the strengths of the TNO, Frisby, and YRDS3 methods for children of different school ages by comparing their testability, repeatability, and agreement. Methods: A total of 194 children aged 3–15 years were divided into preschool, lower primary, upper primary, and secondary groups. During a one-month period, each child completed the TNO, Frisby, and YRDS3 tests once during each of the three clinic visits. The testability, repeatability, and agreement of the three tests were compared with each other. Stereoacuity thresholds were log10-transformed for analysis. Repeatability between consecutive assessments was quantified using repeatability coefficients, and inter-test agreement was evaluated using Bland–Altman analysis with 95% limits of agreement. Results: Preschool testability differed among methods in R1 (p = 0.014), ranging from 80.9% for Frisby to 95.6% for TNO, and increased descriptively with repeated testing. TNO had the highest testability in preschool (95.6%) and lower primary (100.0%). All these 3 tests achieved 100% testability in the upper primary and secondary. YRDS3 had the best first-to-second assessment repeatability coefficients across age groups (0.164–0.317 log10 arcsec). Repeatability coefficients were generally lower for second-to-third assessment than for first-to-second assessment, particularly in younger children. Stereoacuity thresholds differed among the methods within each age group (all p < 0.001). Frisby had the lowest mean thresholds (32.2–47.6 arcsec). Bland–Altman analysis of the mean thresholds in first-to-third assessment showed differences. The 95% limits of agreement were narrowest for YRDS3-TNO (−0.380–0.159) log10 arcsec, followed by TNO-Frisby (−0.019–0.710) log10 arcsec and YRDS3-Frisby (−0.159–0.626) log10 arcsec. Conclusions: TNO demonstrated favorable initial testability in preschoolers, while YRDS3 generally showed higher repeatability. When initial responses are unclear, it could be helpful to repeat the evaluation. The same stereotest should be applied during follow-up because of the limited agreement between approaches.

Authors

Institutions

Publication Details

Journal
Children
Published
2026-11-25
DOI
https://doi.org/10.3390/children13121648
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Stereoacuity Assessment in Children: Testability, Repeatability, and Inter-Test Agreement Among TNO, Frisby and YRDS3 Stereotests

Jie Hao, Lei Li, Jing Fu, Yiyang Zhao
1 links
Children
Ophthalmology and Visual Impairment Studies
article

Stereoacuity Assessment in Children: Testability, Repeatability, and Inter-Test Agreement Among TNO, Frisby and YRDS3 Stereotests

Jie Hao, Lei Li, Jing Fu, Yiyang Zhao
article en

Abstract

Background/Objectives: To identify the strengths of the TNO, Frisby, and YRDS3 methods for children of different school ages by comparing their testability, repeatability, and agreement. Methods: A total of 194 children aged 3–15 years were divided into preschool, lower primary, upper primary, and secondary groups. During a one-month period, each child completed the TNO, Frisby, and YRDS3 tests once during each of the three clinic visits. The testability, repeatability, and agreement of the three tests were compared with each other. Stereoacuity thresholds were log10-transformed for analysis. Repeatability between consecutive assessments was quantified using repeatability coefficients, and inter-test agreement was evaluated using Bland–Altman analysis with 95% limits of agreement. Results: Preschool testability differed among methods in R1 (p = 0.014), ranging from 80.9% for Frisby to 95.6% for TNO, and increased descriptively with repeated testing. TNO had the highest testability in preschool (95.6%) and lower primary (100.0%). All these 3 tests achieved 100% testability in the upper primary and secondary. YRDS3 had the best first-to-second assessment repeatability coefficients across age groups (0.164–0.317 log10 arcsec). Repeatability coefficients were generally lower for second-to-third assessment than for first-to-second assessment, particularly in younger children. Stereoacuity thresholds differed among the methods within each age group (all p < 0.001). Frisby had the lowest mean thresholds (32.2–47.6 arcsec). Bland–Altman analysis of the mean thresholds in first-to-third assessment showed differences. The 95% limits of agreement were narrowest for YRDS3-TNO (−0.380–0.159) log10 arcsec, followed by TNO-Frisby (−0.019–0.710) log10 arcsec and YRDS3-Frisby (−0.159–0.626) log10 arcsec. Conclusions: TNO demonstrated favorable initial testability in preschoolers, while YRDS3 generally showed higher repeatability. When initial responses are unclear, it could be helpful to repeat the evaluation. The same stereotest should be applied during follow-up because of the limited agreement between approaches.

ChildrenVol. 13(12)
Beijing Tongren Hospital (CN), Capital Medical University (CN)
National Natural Science Foundation of China
Good health and well-being
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon