A controllable magnetic prefocusing method for improving the detection consistency of wear particles

Reliable online monitoring of wear particles is important for early fault warning in lubricated mechanical systems. However, random radial entry positions may cause response variation in wear particle sensors, even for particles with identical size and material. To reduce this entrance state uncertainty, this study proposes a controllable magnetic prefocusing method for ferromagnetic wear particles before downstream detection. A segmented soft iron wire array is arranged along the axis of a coaxial annular channel, and an external excitation coil regulates the magnetic field and radial gradient. A COMSOL–MATLAB framework couples magnetic field calculation with particle trajectory simulation. Particle motion is described by free radial migration in annular laminar flow followed by wall sliding along a polytetrafluoroethylene (PTFE) coated inner guiding boundary. The focusing distance and critical capture radius are defined to evaluate focusing efficiency and radial entrance coverage. The results show that the segmented magnetic wire array generates repeated radial gradient peaks within a 30 mm prefocusing length. For particles released near the outer boundary, the effective capture threshold lies between 60 and 70 μm under the selected condition. Increasing the excitation current shortens the focusing distance and expands the critical capture radius, but the gain decreases at high current; 0.5–0.6 A is effective for the present configuration. Higher flow velocity reduces the critical capture radius by limiting the residence time available for radial migration. Coupling with a representative downstream sensing model further demonstrates that magnetic prefocusing suppresses the position-induced component of response variation by regulating particle entrance positions. The method provides an upstream spatial conditioning strategy for improving the detection consistency of ferromagnetic wear particles.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-11-25
DOI
https://doi.org/10.1088/1361-6501/aec6c3
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A controllable magnetic prefocusing method for improving the detection consistency of wear particles

Bo Zhang, Lichen Shi, Haitao Wang, Jiaqi Wang et al.
1 links
Measurement Science and Technology
Machine Fault Diagnosis Techniques
article

A controllable magnetic prefocusing method for improving the detection consistency of wear particles

Bo Zhang, Lichen Shi, Haitao Wang, Jiaqi Wang, Sheng Ai, Xiangxu Meng
article en

Abstract

Reliable online monitoring of wear particles is important for early fault warning in lubricated mechanical systems. However, random radial entry positions may cause response variation in wear particle sensors, even for particles with identical size and material. To reduce this entrance state uncertainty, this study proposes a controllable magnetic prefocusing method for ferromagnetic wear particles before downstream detection. A segmented soft iron wire array is arranged along the axis of a coaxial annular channel, and an external excitation coil regulates the magnetic field and radial gradient. A COMSOL–MATLAB framework couples magnetic field calculation with particle trajectory simulation. Particle motion is described by free radial migration in annular laminar flow followed by wall sliding along a polytetrafluoroethylene (PTFE) coated inner guiding boundary. The focusing distance and critical capture radius are defined to evaluate focusing efficiency and radial entrance coverage. The results show that the segmented magnetic wire array generates repeated radial gradient peaks within a 30 mm prefocusing length. For particles released near the outer boundary, the effective capture threshold lies between 60 and 70 μm under the selected condition. Increasing the excitation current shortens the focusing distance and expands the critical capture radius, but the gain decreases at high current; 0.5–0.6 A is effective for the present configuration. Higher flow velocity reduces the critical capture radius by limiting the residence time available for radial migration. Coupling with a representative downstream sensing model further demonstrates that magnetic prefocusing suppresses the position-induced component of response variation by regulating particle entrance positions. The method provides an upstream spatial conditioning strategy for improving the detection consistency of ferromagnetic wear particles.

Measurement Science and Technology
Xi'an University of Architecture and Technology (CN)
Key Research and Development Projects of Shaanxi Province
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon