A Comparative Evaluation of Similarity Metrics in Normal and Synthetically Varied Kinematic Gait Waveforms

Introduction Waveform similarity in gait, reflecting fluctuations in spatiotemporal and kinematic parameters across strides, is a crucial indicator of locomotor adaptability and pathology. While discrete gait parameters are widely used, they neglect subtle waveform-level differences that may reveal meaningful variations, for example within the waveform course (e.g., additional local extrema), which are ignored when comparing discrete parameters (e.g., range) alone. This study systematically evaluates six waveform similarity metrics: Dynamic Time Warping (DTW), Q-similarity (QS), Modal Assurance Criterion (MAC), Coherence (COH), Pearson correlation coefficient (PCC), and the R 2 -parameter of the Linear Fit Method (LFM (R 2)), determining their sensitivity, detection rate, and consistency in identifying induced gait variation, both within and between subjects. Methods Sagittal hip, knee, and ankle gait kinematics were derived from 20 healthy participants using 3D optical motion capture. Induced variations (amplitude, range, phase, frequency, and offset) were applied to the recorded waveforms, each with multiple severity levels. Semi‐parametric repeated‐measures ANOVAs based on the ANOVA‐type statistic tested the interaction of joint angle, similarity metric, and comparison type for natural variability, and the interaction of joint angle, similarity metric, and severity level within each induced variation type. Sensitivity was quantified as Kruskal–Wallis effect sizes (ε 2) relative to natural within‐subject and between‐subject variability. Detection rates were evaluated against a natural‐variability threshold, and Kendall’s W assessed the consistency with which participants’ rankings of severity levels agreed within each metric and variation type. Results Significant three-way interactions were found for natural variability (joint angle, similarity metric, and comparison type) and for induced variability (joint angle, similarity metric, and severity level within each variation type). Metric performance varied substantially by joint, variation type, and level of comparison. DTW and Q-similarity showed the broadest and most consistent sensitivity across variation types, while statistic-based metrics showed limited sensitivity for affine transformations by construction. Sensitivity and consistency did not always align. Discussion Waveform similarity assessment is highly context dependent, and no universally superior metric exists. Both sensitivity and consistency should be assessed independently, and metric selection should be guided by the expected type of variation and the joint under investigation. This study establishes a methodological foundation for context-specific waveform similarity metric selection in kinematic waveform analysis, improving the objectivity and interpretability of gait assessment.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2026-11-25
DOI
https://doi.org/10.3389/fbioe.2026.1978191
Primary Topic
Gait Recognition and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Comparative Evaluation of Similarity Metrics in Normal and Synthetically Varied Kinematic Gait Waveforms

Steven Simon, Carlo Dindorf, Jonas Dully, Bernd J. Stetter et al.
Frontiers in Bioengineering and Biotechnology
Gait Recognition and Analysis
article

A Comparative Evaluation of Similarity Metrics in Normal and Synthetically Varied Kinematic Gait Waveforms

Steven Simon, Carlo Dindorf, Jonas Dully, Bernd J. Stetter, Michael Fröhlich, Stephan Becker
article en

Abstract

Introduction Waveform similarity in gait, reflecting fluctuations in spatiotemporal and kinematic parameters across strides, is a crucial indicator of locomotor adaptability and pathology. While discrete gait parameters are widely used, they neglect subtle waveform-level differences that may reveal meaningful variations, for example within the waveform course (e.g., additional local extrema), which are ignored when comparing discrete parameters (e.g., range) alone. This study systematically evaluates six waveform similarity metrics: Dynamic Time Warping (DTW), Q-similarity (QS), Modal Assurance Criterion (MAC), Coherence (COH), Pearson correlation coefficient (PCC), and the R 2 -parameter of the Linear Fit Method (LFM (R 2)), determining their sensitivity, detection rate, and consistency in identifying induced gait variation, both within and between subjects. Methods Sagittal hip, knee, and ankle gait kinematics were derived from 20 healthy participants using 3D optical motion capture. Induced variations (amplitude, range, phase, frequency, and offset) were applied to the recorded waveforms, each with multiple severity levels. Semi‐parametric repeated‐measures ANOVAs based on the ANOVA‐type statistic tested the interaction of joint angle, similarity metric, and comparison type for natural variability, and the interaction of joint angle, similarity metric, and severity level within each induced variation type. Sensitivity was quantified as Kruskal–Wallis effect sizes (ε 2) relative to natural within‐subject and between‐subject variability. Detection rates were evaluated against a natural‐variability threshold, and Kendall’s W assessed the consistency with which participants’ rankings of severity levels agreed within each metric and variation type. Results Significant three-way interactions were found for natural variability (joint angle, similarity metric, and comparison type) and for induced variability (joint angle, similarity metric, and severity level within each variation type). Metric performance varied substantially by joint, variation type, and level of comparison. DTW and Q-similarity showed the broadest and most consistent sensitivity across variation types, while statistic-based metrics showed limited sensitivity for affine transformations by construction. Sensitivity and consistency did not always align. Discussion Waveform similarity assessment is highly context dependent, and no universally superior metric exists. Both sensitivity and consistency should be assessed independently, and metric selection should be guided by the expected type of variation and the joint under investigation. This study establishes a methodological foundation for context-specific waveform similarity metric selection in kinematic waveform analysis, improving the objectivity and interpretability of gait assessment.

Frontiers in Bioengineering and BiotechnologyVol. 14
Karlsruhe Institute of Technology (DE), Rheinland-Pfälzische Technische Universität Kaiserslautern-Landau (DE)
Bundesministerium für Wirtschaft und Klimaschutz
Good health and well-being
Gait Recognition and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon