Intra- and Inter-Rater Reliability of Inter-Recti Distance Measurement Using B-Mode and Panoramic Ultrasound Imaging
Background: Ultrasound imaging (USI) is widely used to quantify the inter-recti distance (IRD), but measurement procedures vary and evidence on examiner experience and panoramic-mode (PAN-mode) imaging remains limited. This study evaluated the intra- and inter-rater reliability of IRD measurements obtained using conventional B-mode and PAN-mode, examined the influence of examiner experience, and assessed the effect of repeated measurements on reliability and measurement error. Methods: Forty-four women underwent two measurement series on the same day, separated by 15 min. The IRD was measured at rest and during rectus abdominis activation using B-mode and PAN-mode. Three repeated images were acquired for each condition. Reliability was assessed using ICC(2,1), ICC(2,2), and ICC(2,3), together with the standard error of measurement (SEM) and smallest detectable difference (SDD). Results: Intra- and inter-rater reliability for the absolute IRD was excellent in both imaging modes, with single-measurement ICCs ≥ 0.981 for inter-rater and ≥0.992 for intra-rater reliability. Averaging repeated measurements reduced the SEM and SDD. Reliability of the activity-minus-rest difference (Δ) was acceptable to excellent within raters (ICC 0.918–0.973) but moderate to good between raters (ICC 0.632–0.812). Conclusions: B-mode and PAN-mode provide highly reliable IRD measurements in trained examiners, including beginners. Repeated measurements reduce measurement error. The activity-minus-rest difference (Δ) demonstrated lower inter-rater reliability than absolute IRD measurements and should therefore be interpreted cautiously, particularly when measurements are obtained by different examiners.
Authors
- Małgorzata Kilon (ORCID: https://orcid.org/0000-0001-5281-7950)
- Tomasz Wolny (ORCID: https://orcid.org/0000-0001-7910-757X)
- Mateusz Madejski
- Rafał Gnat (ORCID: https://orcid.org/0000-0002-8862-9895)
- Robert Irzmański (ORCID: https://orcid.org/0000-0001-9276-7273)
- Krzysztof Szablewski
- Katarzyna Monika Glibov (ORCID: https://orcid.org/0000-0003-4504-1511)
Institutions
- Medical University of Silesia (PL)
- Medical University of Warsaw (PL)
- Medical University of Lodz (PL)
- Akademii Wychowania Fizycznego im. Jerzego Kukuczki w Katowicach (PL)
Publication Details
- Journal
- Journal of Clinical Medicine
- Published
- 2026-11-25
- DOI
- https://doi.org/10.3390/jcm15239249
- Primary Topic
- Reliability and Agreement in Measurement
- Type
- article
- Field-Weighted Citation Impact
- 0.00