High-density bead-diode arrays enable rapid drift-resistant single-molecule counting in microliter tear samples

Single-molecule digital immunoassays reach attomolar sensitivity by counting individual immunocomplexes, yet only a fraction of the microbeads is ultimately analyzed; microbead sampling efficiency typically falls below 40%, and this under-sampling limits not only ultimate sensitivity but also measurement precision. Because readout must then be referenced to an external standard, specimen-to-specimen matrix effects and environmental fluctuation readily introduce bias. Here we report a self-rectifying fluidic-diode array that locks 92% of 4 × 10 5 silica microbeads into a high-density monolayer, providing a statistically sufficient microbead count to drive Poisson-based absolute molecule enumeration. Each flow–trap junction rectifies a single microbead and reroutes the carrier fluid, eliminating clustering and microbead loss. Concurrently, nanoscale non-target impurities are laterally flushed out of the detection zone. Silica-supported quantum-dot nanoprobes deliver a 3.7-fold higher fluorescence signal intensity than magnetic-microbead counterparts and enable wide-field digital readout, capturing all positive and negative microbead states within a single camera frame and making calibration-curve-free, direct molecule counting practically feasible. In artificial tears, the platform achieves limits of detection of 13 aM for IgE, 50 aM for TNF-α, and 810 aM for neurofilament light chain, with 92–107% spike recovery. By using adaptive standard addition as a drift-resistant internal calibration within each specimen, these high-density microbead arrays bring digital single-bead immunoassays from laboratory instrumentation towards point-of-care use, enabling rapid quantification of proteins in microliter tear samples. In a 20-participant feasibility cohort, Arm A (n = 10) compared tear measurements head-to-head with a commercial digital lateral-flow assay, and Arm B (n = 10) measured IgE, TNF-α and NfL in parallel as three single-analyte assays after 1:32 dilution. Each measurement required 2.2 µL of tear, was completed within 37 min, and needed no external calibration curve.

Authors

Institutions

Publication Details

Journal
Journal of Nanobiotechnology
Published
2026-11-25
DOI
https://doi.org/10.1186/s12951-026-05212-5
Primary Topic
Advanced Biosensing Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

High-density bead-diode arrays enable rapid drift-resistant single-molecule counting in microliter tear samples

Zhiting Peng, Lap Tak Hung, Ho Cheung Shum, Yau Kei Chan et al.
3 links
Journal of Nanobiotechnology
Advanced Biosensing Techniques and Applications
article

High-density bead-diode arrays enable rapid drift-resistant single-molecule counting in microliter tear samples

Zhiting Peng, Lap Tak Hung, Ho Cheung Shum, Yau Kei Chan, Tianzhun Wu, Hua Wang, Yingzhu Yu
article en

Abstract

Single-molecule digital immunoassays reach attomolar sensitivity by counting individual immunocomplexes, yet only a fraction of the microbeads is ultimately analyzed; microbead sampling efficiency typically falls below 40%, and this under-sampling limits not only ultimate sensitivity but also measurement precision. Because readout must then be referenced to an external standard, specimen-to-specimen matrix effects and environmental fluctuation readily introduce bias. Here we report a self-rectifying fluidic-diode array that locks 92% of 4 × 10 5 silica microbeads into a high-density monolayer, providing a statistically sufficient microbead count to drive Poisson-based absolute molecule enumeration. Each flow–trap junction rectifies a single microbead and reroutes the carrier fluid, eliminating clustering and microbead loss. Concurrently, nanoscale non-target impurities are laterally flushed out of the detection zone. Silica-supported quantum-dot nanoprobes deliver a 3.7-fold higher fluorescence signal intensity than magnetic-microbead counterparts and enable wide-field digital readout, capturing all positive and negative microbead states within a single camera frame and making calibration-curve-free, direct molecule counting practically feasible. In artificial tears, the platform achieves limits of detection of 13 aM for IgE, 50 aM for TNF-α, and 810 aM for neurofilament light chain, with 92–107% spike recovery. By using adaptive standard addition as a drift-resistant internal calibration within each specimen, these high-density microbead arrays bring digital single-bead immunoassays from laboratory instrumentation towards point-of-care use, enabling rapid quantification of proteins in microliter tear samples. In a 20-participant feasibility cohort, Arm A (n = 10) compared tear measurements head-to-head with a commercial digital lateral-flow assay, and Arm B (n = 10) measured IgE, TNF-α and NfL in parallel as three single-analyte assays after 1:32 dilution. Each measurement required 2.2 µL of tear, was completed within 37 min, and needed no external calibration curve.

Journal of Nanobiotechnology
Central South University (CN), Chinese Academy of Sciences (CN), Hong Kong Science and Technology Parks Corporation (HK), InferVision (China) (CN), Shenzhen Institutes of Advanced Technology (CN), Envision Energy (China) (CN), University of Hong Kong (HK)
Good health and well-being
Advanced Biosensing Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon