Storage Sizing and Adaptive Reporting Control for Self-Powered IoT Sensor Nodes: A Year-Long Simulation Study of Indoor and Outdoor Solar Harvesting in a Tropical Climate
Energy-harvesting wireless sensor nodes offer the potential for maintenance-free IoT deployments. However, achieving reliable energy autonomy requires two interdependent design decisions: selecting an appropriate energy storage capacity and adapting the reporting rate according to expected energy availability. This paper investigates these decisions through a year-long simulation at one-minute resolution for two solar-powered sensor nodes: a low-power indoor LoRa sensor powered by a supercapacitor and an outdoor particulate matter monitoring node powered by a 500 mAh LiFePO4 battery. Solar irradiance is modelled using a clear-sky model combined with a Markov-based weather process, with monthly sky-state probabilities representing tropical monsoon patterns. Indoor energy harvesting is modelled using an office lighting profile that accounts for weekends and holidays. Four reporting policies are evaluated across three independently generated weather years: a greedy policy operating at the maximum reporting rate, a static reporting interval based on annual mean harvested energy, a smooth state-of-charge threshold-based policy, and a predictive energy-neutral controller using a moving-average energy forecast over a one-hour window. For the indoor node, energy storage capacity emerges as the dominant design factor. Under the static reporting policy, increasing supercapacitor capacity from 2 F to 5 F reduces downtime from 16.0% to 0.46%, primarily by enabling the node to bridge extended periods of reduced energy harvesting during weekends and holidays rather than merely daily lighting variations. With 5 F storage, the predictive controller further reduces downtime to 0.08% and the maximum reporting gap from 18.4 h to 7.5 h, while delivering 156 reports per day compared with 130 for the static policy. This performance approaches the estimated energy-balance limit of 155 reports per day. However, no reporting policy is universally optimal, as the static policy achieves the lowest downtime at 10 F storage. For the outdoor node, a static reporting interval configured using annual mean harvested energy results in 5.5% downtime with a 4 cm² solar panel due to prolonged monsoon-related overcast conditions. In contrast, both adaptive reporting policies maintain uninterrupted operation throughout the simulated years while achieving comparable or higher reporting rates. These results demonstrate the importance of jointly optimizing energy storage and reporting control under variable harvesting conditions. The study is based on synthetic environmental profiles and simulation models; validation using measured irradiance data and hardware experiments is necessary to establish practical deployment performance.
Authors
- K. Balaji Nanda Kumar Reddy
- N. Pushpalatha
- Thinnaluri Jyothi
- Irala Suneetha
- P. Harish
- S. Rohini
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-25
- DOI
- https://doi.org/10.5281/zenodo.24523771
- Primary Topic
- Energy Harvesting in Wireless Networks
- Type
- article
- Field-Weighted Citation Impact
- 0.00