Comparison of the effects of the Invisalign Palatal Expander and an acrylic-bonded expansion appliance on craniofacial structures using finite element analysis
Background The Invisalign Palatal Expander (IPE) has recently emerged as an alternative to conventional rapid maxillary expansion appliances in growing patients, but evidence on its biomechanical behavior remains limited. This study compared the biomechanical responses produced by the IPE and a conventional acrylic-bonded expansion appliance (ABEA). Methods A patient-specific 3-dimensional finite element model of the craniofacial complex was reconstructed from cone-beam computed tomography data of a patient aged 8–10 years in the mixed dentition with maxillary transverse deficiency. Both appliances were analyzed under identical boundary and loading conditions, with a total prescribed transverse expansion of 10 mm (5 mm per side). Displacement and stress in the teeth, periodontal ligament, cortical bone, trabecular bone, and circummaxillary sutures were evaluated, together with opening of the midpalatal suture. Results Both appliances produced transverse expansion, but the responses differed. The ABEA produced greater total tooth displacement (4.533 vs 2.497 mm), cortical bone and sutural displacement (4.617 vs 2.119 mm), and trabecular bone displacement (3.378 vs 1.564 mm). Periodontal ligament stress was also higher with the ABEA (3.957 vs 2.238 MPa). Peak dental von Mises stresses were comparable (75.787 vs 74.899 MPa), but the ABEA showed broader stress propagation, whereas the IPE showed more localized transmission with lower magnitudes. The midpalatal suture opened in both models, in a wedge-shaped pattern wider anteriorly than posteriorly, and the opening was greater with the ABEA (5.570 mm anteriorly and 4.100 mm posteriorly) than with the IPE (2.414 and 1.928 mm, respectively). Conclusions Both systems achieved a similar overall expansion pattern but differed biomechanically. The ABEA produced more extensive displacement and stress transmission, whereas the IPE produced a more controlled response. These differences reflect force transmission under the simulated conditions rather than clinical superiority of either appliance.
Authors
- Esra Ağaoğlu Mogul (ORCID: https://orcid.org/0000-0003-0049-3004)
- Zeynep Betül Yavuz
Institutions
- Biruni University (TR)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-25
- DOI
- https://doi.org/10.21203/rs.3.rs-11471471/v1
- Primary Topic
- Orthodontics and Dentofacial Orthopedics
- Type
- preprint